Set the STAB TRIM 3 switch on the control stand to ON.


 S 865-011
 S 865-014
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-48-00
 ALL  ú ú 01 Page 504 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 865-015
 WARNING:_______ MOVE ALL PERSONS AND EQUIPMENT AWAY FROM THE STABILIZER AND
 THE ELEVATOR SURFACES BEFORE YOU MOVE THE STABILIZER.  THE
 STABILIZER AND THE ELEVATOR SURFACES CAN MOVE QUICKLY AND CAUSE

 INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (5)  Use the STAB TRIM ALTN switches to move the stabilizer until the "B" dimension is 17.59-17.63 inches.
 NOTE: The "B" dimension is the distance along the ballscrew between
____ the surfaces of the ballnut and the ballscrew stops
 S 865-016
 (6)  
Set the STAB TRIM 3 switch to CUTOUT.

 S 865-017

 (7)  
Open these circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  
P7, Overhead Circuit Breaker Panel 1) 7E20, STAB TRIM R S/O VALVE 2) 7E23, STAB TRIM ALTN CONT


 S 865-018
 (8)  
If the hydraulic power is not necessary, do this task: "Remove Hydraulic Power" (AMM 29-11-00/201).

 S 015-019

 (9)  
Open the 315A access door.

 S 825-020

 (10)
 Make sure the indication for the applicable transmitter on the EICAS flight controls maintenance page shows 4.49-4.51 degrees down.

 (a)  
If the indication is out of the tolerance, adjust the transmitter control rod: 1) Loosen the jamnut at the two ends of the applicable


 transmitter control rod. 2) Adjust the control rod until the applicable EICAS
 indication shows 4.49-4.51 degrees down. 3) Tighten the jamnut at the two ends of the control rod. 4) Make sure that the EICAS indication is in the tolerance.
 S 415-021
 (11)
 Close the 315A access door.

 (12)
 Set the STAB TRIM 3 switch to NORM.


 S 865-022
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-48-00
 ALL  ú ú 01 Page 505 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 865-023
 (13)
 Remove the DO-NOT-CLOSE tags and close these circuit breakers:

 (a)  
P7, Overhead Circuit Breaker Panel
 1) 7E7, STAB TRIM L S/O VALVE
 2) 7E6, STAB TRIM L CONT
 3) 7E19, STAB TRIM R CONT

 

 S 865-024
 (14) If the electrical power is not necessary, do this task:  "Remove Electrical Power" (AMM 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-48-00
 ALL  ú ú 01 Page 506 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 HORIZONTAL STABILIZER POSITION TRANSMITTER - REMOVAL/INSTALLATION
____________________________________________________________________
 1.  General_______
 A. There are four tasks in this procedure. The procedure has these parts:
 (1)  
The removal of the horizontal stabilizer position transmitter module

 (2)  
The installation of the replacement transmitter module

 (3)  
The adjustment of the transmitter module

 (4)  
The removal of the horizontal stabilizer position transmitter assembly

 (5)  
The installation of the replacement transmitter assembly

 (6)  
The adjustment of the transmitter assembly.

 B.  
The removal and installation procedure is the same for the left, the right or the center stabilizer position transmitter module.


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 4(23)