Fan Duct Cowl and Thrust Reverser Opening Actuator
Figure 202
REVERSER OPENING ACTUATOR
INLET FITTING
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
78-31-00
ALL ú ú C02 Page 208 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////
2) Make sure the word "LOCKED" shows on the bottom of the extended piston of the reverser opening actuator.
(g)
Install the actuator lock on the extended piston rod.
(h)
Open the valve on the hand pump and let the reverser half be held by the locked reverser opening actuator.
WARNING: DO NOT LET THE RETURN VALVE ON THE HAND PUMP STAY IN THE
_______ OPEN POSITION EXCEPT WHEN YOU LOWER THE COWL. IF YOU LEAVE T THE VALVE IN THE OPEN POSITION, THE ACTUATOR FLUID CAN CONTINUE TO DRAIN OUT OF THE ACTUATOR INTO THE PUMP. THIS CAN REDUCE THE SNUBBING ACTION OF THE ACTUATOR WHEN YOU CLOSE THE COWL. REDUCED SNUBBING ACTION CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
(i) After the reverser half is held by the locked reverser opening actuator, close the valve on the hand pump.
CAUTION: DO NOT DISCONNECT THE HAND PUMP HOSE FROM THE REVERSER
_______ OPENING ACTUATOR WHILE THE HOSE IS PRESSURIZED. A SPRAY OF OIL CAN COME FROM THE HAND PUMP HOSE IF IT IS DISCONNECTED WHILE PRESSURIZED.
(j) If it is necessary, disconnect the hand pump hose from the reverser opening actuator. 1) Install dust caps on the inlet fitting on the reverser
opening actuator, and on the hand pump hose.
TASK 78-31-00-412-020-C00
5. Close the Thrust Reverser - Pump Procedure
__________________________________________
A. Equipment
(1)
C78005 Pump - Hand, Thrust reverser Opening System
(2)
C78016-1 Tool - Latching, Reverser
(3)
C78010-1 Tool - Latching, Reverser (Optional to C78016-1)
B.
Consumable Materials
(1)
Oil - Engine (AMM 70-10-01/201)
C.
References
(1)
AMM 27-81-00/201, Leading Edge Flap and Slat Control System
(2)
AMM 71-11-02/201, Fan Cowl Panels
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
78-31-00
ALL ú ú C02 Page 209 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////
D. Access
(1)
Location Zones
101 Control Cabin - Left
102 Control Cabin - Right
217 Main Wheel Well - Right
504/604 Thrust Reverser - Left
505/605 Thrust Reverser - Right
(2)
Access Panels
502/602 Fan Cowl - Left
503/603 Fan Cowl - Right
E. Procedure
S 412-068-C00
WARNING: USE MUCH CAUTION WHEN YOU CLOSE THE THRUST REVERSER IN LARGE
_______ WINDS OR IN SUDDEN WIND CONDITIONS. IF YOU DO NOT USE CAUTION, INJURY TO PERSONS AND DAMAGE TO EQUIPMENT CAN OCCUR.
DO NOT OPERATE THE OPENING SYSTEM FOR THE THRUST REVERSER IF THE WIND VELOCITY IS MORE THAN 40 KNOTS. THE OPENING SYSTEM FOR THE THRUST REVERSER CAN HAVE A FAILURE IN LARGE WINDS WHICH CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
CAUTION: DO NOT CAUSE THE THRUST REVERSER SLEEVES TO MOVE TO THE
_______ DEPLOYED POSITION WHEN THE THRUST REVERSER IS OPEN. THIS CAN CAUSE DAMAGE TO THE TRANSLATING SLEEVE AND THE LEADING EDGE FLAP.
CAUTION: DAMAGE TO THE FIRESEALS ON THE TURBINE EXHAUST SLEEVE CAN OCCUR
_______ WHEN YOU CLOSE THE THRUST REVERSER. MAKE SURE THERE IS NO INTERFERENCE BETWEEN THE FIRESEALS AND THE THRUST REVERSER.
(1) Close the thrust reverser:
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 EXHAUST(25)