(g)
Adjust the door down switch at the other end of the door.
S 825-025
(2) Adjust the door up switches as follows (Fig. 512):
NOTE: You can use this procedure for the two door up switches.
____
(a)
If it is necessary to get access to the switches, open the two ceiling panels from second row of panels that are inboard of the door.
(b)
Install the weather barrier that encloses the lift mechanism.
CAUTION:_______IN CASE THE DOOR DOES NOT OPEN, STOP IMMEDIATELY. DO NOT OPERATE THE DOOR CONTROL SWITCH. HOLDING THE DOOR CONTROL SWITCH MAY DAMAGE THE ACTUATOR. WAIT AT LEAST 1 MINUTE BEFORE SECOND ATTEMPT. IF THE DOOR STILL DOES NOT OPEN, WAIT AT LEAST 10 MINUTES BEFORE THIRD ATTEMPT.
(c)
Open the door and manually turn the lift power unit to get the correct clearance between the rotary actuator arm and the door upstop as shown in View A-A.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
52-32-00
ALL ú ú 04 Page 537 ú Oct 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
A
DOOR UP SWITCH DOOR DOWN (2 LOCATIONS) SWITCH (2 LOCATIONS)
A
DOOR DOWN STOP
DOOR
DOWN ROTARY SWITCH ACTUATOR
DOWNSTOP CLEARANCE
0.20 INCH UPSTOP CLEARANCE ROTARY
0.20 INCH 1 ACTUATOR 1
0.06-0.18 INCH0.09-0.21 INCH 2
2 DOOR UP SWITCH
0.063 TO 0.071 INCH SWITCH CLEARANCE
3
0.032 TO 0.040 INCH SWITCH CLEARANCE
ROTARY 4
0.063 TO 0.071 INCH ACTUATOR
POINT "B"
SWITCH CLEARANCE ARM
POINT "F"
0.156 DIA
ROTARY ACTUATOR
ROTARY RIGGING GAGE LINK
ACTUATOR
ARM
DOOR UP SWITCH ADJUSTMENT DOOR DOWN SWITCH ADJUSTMENT
A-A A-A
1
UPSTOP OR DOWNSTOP CLEARANCE FOR SWITCH OR MECHANISM ADJUSTMENT (LIFT POWER UNIT CRANKED MANUALLY TO OBTAIN 3 SWITCH CLEARANCE APPLICABLE IF 65B83648-1 CLEARANCE) ROTARY ACTUATOR LINK INSTALLED
2 UPSTOP OR DOWNSTOP CLEARANCE AFTER 4 SWITCH CLEARANCE APPLICABLE IF 65B83648-2 ELECTRICAL OPERATION STOPS ROTARY ACTUATOR LINK INSTALLED
Door Up and Door Down Switch Adjustment
Figure 512
H36786
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
52-32-00
ALL ú ú 03 Page 538 ú Jun 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
B
A
B LATCH LOCK
SECTOR
A
AUXILIARY DOOR
CLOSED SWITCH
DOOR
CLOSED
SWITCH SWITCH
SWITCH
MOUNTING
BRACKET
1.09 INCHES FREE POSITION OF INCHES 1.49 1.54
CONTACTING STRIKING SWITCH PLUNGER (NOT FREE POSITION OF SWITCH
SURFACE) SWITCH ACTUATOR) PLUNGER (NOT CONTACTING
LATCH FITTING
SWITCH
MOUNTING SWITCH
BRACKET ACTUATOR
DOOR DOOR SILL LOWER LATCH
CAM SHAFT
A-A B-B
Door Closed Switches Adjustment
Figure 513
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
52-32-00
ALL ú ú 03 Page 539 ú Jun 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
H36815
A
747-400
MAINTENANCE MANUAL
MASTER LATCH LOCK SWITCH
A
A
LATCH LOCK SECTOR
LOWER LATCH CAM SHAFT
MASTER LATCH LOCK SWITCH MASTER LATCH LOCK SWITCH
SWITCH MOUNTING BRACKET SWITCH MOUNTING BRACKET
SWITCH ACTUATOR BRACKET BRACKET SWITCH ACTUATOR
0.983 INCH STARTING FREE HEIGHT POSITION 0.752 INCH CORRECT MEASURED HEIGHT
LATCHES LOCKED POSITION LATCHES UNLOCKED POSITION
A-A A-A
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 舱门 DOORS 2(93)