52-31-00
ALL ú ú 02 Page 510 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
ISOLATION
PRESSURE
RELAY, R1104
SYSTEM CONNECTOR
(BELOW ELECTRICAL CONNECTOR)
PRESSURE PROBE
Pressure Switch and Isolation Relay
Figure 507
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
52-31-00
ALL ú ú 02 Page 511 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
B26859
A
747-400
MAINTENANCE MANUAL
LATCH ACTUATOR TEST PANEL, H482
NOSE DOOR CONTROL AND LIGHTS MODULE, H121DOOR LATCH ANNUNCIATOR, H449
DOOR CLOSED ANNUNCIATOR, H548
Nose Cargo Door Control Panel
Figure 508
C16659
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
52-31-00
ALL ú ú 02 Page 512 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
3) LATCHES 1-4R
4) LATCHES 1-4L
5) LATCHES 5-8R
6) LATCHES 5-8L
E. Procedure
S 865-202
CAUTION: ALLOW 4 MINUTES COOLING TIME BETWEEN THE DOOR OPENING AND
_______ CLOSING. THIS WILL PREVENT THE DRIVE UNIT FROM BECOMING OVERHEATED.
(1) Simultaneously hold the control switches to open the door and look to see these indications:
NOTE: When the door opens or closes it can make unusual noise when
____ the latch pins engage the spherical bearings.
(a)
On the EICAS display: 1) The caution message DOOR NOSE CARGO shows 2) The status message DOOR NOSE CARGO does not show.
(b)
On the synoptic display:
1) The amber nose cargo door shows.
(c)
On the door control and lights panel:
1) White POWER ON light comes on
2) Green LATCHES CLOSED light goes off.
(d)
On the door latch annunciator panel:
1) 16 amber NOT LCHD lights come on
2) 16 green LATCHED lights go off.
(e)
On the door closed annunciator panel:
1) 2 amber DOOR NOT CLOSED lights come on
2) 2 green DOOR CLOSED lights go off.
S 215-004
(2)
When the door is fully opened, make sure the drive unit stops and look to see these indications:
(a)
On the door control and lights panel:
1) Blue DOOR UP light comes on
2) White POWER ON light remains on
3) Green LATCHES CLOSED light remains off.
(b)
On the door latch annunciator panel:
1) 16 amber NOT LCHD lights remain on
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
52-31-00
ALL ú ú 02 Page 513 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
2) 16 green LATCHED lights remain off.
(c) On the door closed annunciator panel:
1) 2 amber DOOR NOT CLOSED lights remain on
2) 2 green DOOR CLOSED lights remain off.
S 215-005
(3)
Release the control switches and look to see these indications:
(a)
On the door control and lights panel:
1) Blue DOOR UP light remains on
2) White POWER ON light goes off.
(b)
On the EICAS display:
1) The caution message DOOR NOSE CARGO remains
(c)
On the synoptic display:
1) The amber nose cargo door remains.
S 215-162
CAUTION: ALLOW 4 MINUTES COOLING TIME BETWEEN THE DOOR OPENING AND
_______ CLOSING. THIS WILL PREVENT THE DRIVE UNIT FROM BECOMING OVERHEATED.
(4)
Simultaneously hold the control switches to close the door and look to see these indications:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 舱门 DOORS 2(10)