• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 05:45来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Put the flap shutoff valve lever to position 2.

 (2)  
Put the valve motor on the shutoff valve.


 S 862-024
 S 862-025
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-81-91
 ALL  ú ú 01 Page 205 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 S 422-026
 (3)  
Engage the motor drive with the valve cam.

 S 432-027

 (4)  
Install the four screws to attach the valve motor to the shutoff valve.

 S 432-028

 (5)  
Install lockwire on the screws.

 S 432-029

 (6)  
Install the electrical connector on the valve motor.

 S 862-045

 (7)  
Remove the DO-NOT-CLOSE tags and close these circuit breakers:

 (a)  
P6-2 Circuit Breaker Panel
 1) FLAP SHUTOFF VALVES

 

 S 712-030
 (8)  Do a test of the shutoff valve.
 TASK 27-81-91-712-031
 6. Standby Drive Shutoff Valve Test
________________________________
 A. References
 (1)  
24-22-00/201, Manual Control

 (2)  
27-81-00/201, Leading Edge Flap and Slat Control System

 B.
Access

 (1)  
Location Zone
 101 Control Cabin, LH
 102 Control Cabin, RH
 216 Main Wheel Well, LH


 C.
Procedure

 (1)  
Supply electrical power (24-22-00/201).


 S 862-032
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-81-91
 ALL  ú ú 01 Page 206 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 S 862-054
 (2)  
Open these circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  
P6-2 Circuit Breaker Panel
 1) ALT TE FLAP DRIVE AC

 

 S 862-033
 (3)  
Put the flap shutoff valve lever at position 1.

 S 862-034

 (4)  
Pressurize hydraulic system B (Ref 27-81-00/201).

 S 862-035

 (5)  
Put the flap control lever to the FLAP UP detent.

 S 862-036

 (6)  
Put the alternate flap arm switch to ARM.

 (a)  
Make sure the STANDBY HYD LOW PRESSURE light comes on.

 (b)  
Make sure the standby hydraulic pump starts.

 (c)  
Make sure the STANDBY HYD LOW PRESSURE light is off.


 S 862-037
 (7)  
Put the alternate flap control switch to DOWN.

 (a)  
Make sure the flap shutoff valve lever is at position 2.

 (b)  
Make sure the leading edge flaps and slats fully extend.


 S 862-053
 (8)  
Put the alternate flap control switch to OFF.

 (a)  
Make sure the leading edge flaps and slats do not move.


 S 862-049
 (9)  
Put the alternate flap arm switch to OFF.

 S 862-052

 (10)
 Make sure the flap shutoff valve lever moves to position 1.

 (11)
 Make sure the leading edge flaps and slats fully retract.


 S 862-050
 NOTE: The leading edge flaps and slats retract because of the
____
 pressurization of hydraulic system B.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-81-91
 ALL  ú ú 01 Page 207 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 872-051
 (12)
 Operate the leading edge devices to bleed the standby hydraulic system:

 (a)  
Put the flap control lever to the FLAP UP detent.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 6(105)