(l)  
Close this circuit breaker:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7A10, ADC L PWR
 (m)  
Make sure bits 12 and 18 are 0.
 S 715-037
 (7)  Do these steps to check the output bus for the Right Stall Warning Master card:
 NOTE: After you open circuit breakers or change the switch
____ position, permit 10 to 15 seconds for the bit conditions to change.
 (a)  
Put E/066/350/01 in the scratchpad.
 (b)  
Push the LSK adjacent to -/---/---/-- prompt.
 (c)  
Make sure bits 11 to 22 are 0.
 (d)  
Open these circuit breakers:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7C14, FLT CONT ELEC 1R AC
 b) 7C15, FLT CONT ELEC 1R DC
 (e)  
Make sure bit 21 is 1.
 (f)  
Close these circuit breakers:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7C14, FLT CONT ELEC 1R AC
 b) 7C15, FLT CONT ELEC 1R DC
 (g)  
Open these circuit breakers:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7E09, MCP L
 b) 7E18, MCP R
 (h)  
Make sure bit 22 is 1.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 31-51-00
 ALL  ú ú 10 Page 508 ú Jun 18/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 (i)  
Close these circuit breakers:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7E09, MCP L
 b) 7E18, MCP R
 (j)  
Open this circuit breaker:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7A14, ADC R PWR
 (k)  
Make sure bit 18 is 1.
 (l)  
Close this circuit breaker:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7A14, ADC R PWR
 (m)  
Make sure bits 12 and 18 are 0.
 S 715-038
 (8)  Do these steps to check the output bus for Crew Alerting card:
 NOTE: After you open circuit breakers or change the switch
____ position, permit 10 to 15 seconds for the bit conditions to change.
 (a)  
Put C/042/350/00 in the scratchpad.
 (b)  
Push the LSK adjacent to -/---/---/-- prompt.
 (c)  
Make sure bits 11 to 22 are 0.
 (d)  
Open these circuit breakers:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7E09, MCP L
 b) 7E18, MCP R
 (e)  
Make sure bit 21 is 1.
 (f)  
Close these circuit breakers:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7E09, MCP L
 b) 7E18, MCP R
 S 715-039
 (9)  Do these steps to check the output bus for the Configuration Warning card:
 NOTE: After you open circuit breakers or change the switch
____ position, permit 10 to 15 seconds for the bit conditions to change.
 (a)  
Put E/057/350/00 in the scratchpad.
 (b)  
Push the LSK adjacent to the -/---/---/-- prompt.
 (c)  
Make sure bits 11 to 22 are 0.
 (d)  
Open this circuit breaker:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7F09, EIU L
 (e)  
Make sure bit 21 is 1.
 (f)  
Close this circuit breaker:
 1)  P7, Overhead Circuit Breaker Panel
 a) 7F09, EIU L
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 31-51-00
 ALL  ú ú 04 Page 509 ú Jun 18/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 (g) 
Open this circuit breaker:
1) P7, Overhead Circuit Breaker Panel a) 7F15, EIU R
 (h) 
Make sure bit 22 is 1.
 (i) 
Close this circuit breaker:
 1)  P7, Overhead Circuit Breaker Panel a) 7F15, EIU R
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 指示/记录系统 2(9)