• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-12 10:04来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 CAUTION: MAKE SURE YOU KNOW THE CORRECT IDS SOFTWARE PART NUMBER
_______ FOR THE EIUs. FOR THE EIUs TO BE AN APPROVED INSTALLATION, THE CORRECT SOFTWARE PART NUMBER MUST BE INSTALLED.
 (b)  Make sure that the IDS software P/N 685-2265-XXX is the same in all three IDUs.
 S 864-149
 (7)  Put the airplane to its usual condition.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 31-61-01
 ALL  ú ú 03 Page 407 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 INTEGRATED DISPLAY UNIT - MAINTENANCE PRACTICES
_______________________________________________
 1.  General_______
 A.  This subject has two tasks. The first task is to clean the CRT face of the integrated display unit (IDU). The second task is to clean the air inlet screen at the rear of the IDU.
 B.  There are six IDUs in the flight compartment. Two IDUs are on the captain's instrument panel. Two IDUs are on the first officer's instrument panel. One IDU is on the center of the instrument panel. One IDU is on the forward electronic panel.
 TASK 31-61-02-102-032
 2.  Integrated Display Unit CRT Cleaning____________________________________
 A.  Standard Tools and Equipment
 (1)  Cloth - Clean, lint-free, cotton
 B.  Consumable Materials
 (1)  B00032 Glass Cleaner Kit - Safe Clens
 C.  Access
 (1)  Location Zone
 221 Control Cabin, LH
 222 Control Cabin, RH

 D.  Procedure
 S 862-033
 (1)  Open these circuit breakers:
 (a)  P7, Overhead Circuit Breaker Panel
 1) 7F8, UPR EICAS
 2) 7F12, ND L
 3) 7F13, PFD L
 4) 7F14, LWR EICAS
 5) 7F17, ND R
 6) 7F18, PFD R

 S 162-045
 CAUTION:_______DO NOT USE SOLVENT TO CLEAN THE IDU'S CRT. DAMAGE TO THE EQUIPMENT CAN OCCUR.
 (2)  Remove grease and dirt from the surface of the IDU display screen with the glass cleaner and cloth.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 31-61-02
 ALL  ú ú 02 Page 201 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 162-037
 (3)  Remove grease and dirt from the IDU's local light sensor with the glass cleaner and cloth.
 NOTE: The local light sensor is on the lower right corner of the
____
 IDU.

 S 862-038
 (4)  Close these circuit breakers:
 (a)  P7, Overhead Circuit Breaker Panel 1) 7F8, UPR EICAS 2) 7F12, ND L 3) 7F13, PFD L 4) 7F14, LWR EICAS 5) 7F17, ND R 6) 7F18, PFD R
 TASK 31-61-02-102-041
 3. Integrated Display Unit Air Inlet Screen Cleaning
_________________________________________________
 A. Standard Tools and Equipment
 (1)  Vacuum Source
 B. References
 (1)  AMM 31-61-02/401, Integrated Display Unit
 C. Access
 (1)  Location Zone
 221 Control Cabin, LH
 222 Control Cabin, RH

 D. Procedure
 S 022-042
 (1)  Remove the IDU (AMM 31-61-02/401).
 (a)  Put the IDU on a stable surface.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 31-61-02
 ALL  ú ú 06 Page 202 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
 (2)  S 162-043Remove all dirt from the inlet screen with a vacuum source.
 NOTE:____ The inlet screen is found at the rear of the IDU.
 (3)  S 422-044Install the IDU (AMM 31-61-02/401).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 指示/记录系统 2(151)