(2)
D00288 Lubricant - Skydrol Assembly Lube, MCS352
(3)
D00153 - Fluid, Hydraulic Fire Resistant - BMS 3-11
B. Parts ~.............................................................................. | AMM | | AIPC | ................. ............................ | FIG | ITEM | NOMENCLATURE | SUBJECT | FIG | ITEM | ................................................................................ | 401 | 1 | Nut | 27-23-51 | 01 | 35 | | | 2 | Washer | | | 30 | | | 3 | Bolt | | | 20 | | | 4 | DC Motor-Operated Shutoff | | | 10 | | | | Valve Assembly | | | | | | 5 | Packing | | | 60 | | | 6 | O-Ring | | | 65 | | | 7 | Packing | | | 55 | | | 8 | Adapter | | | 40,45 | | | | | | | | 2......…........…...................................…...........….....…........1
C. References
(1)
06-09-05/201, Body Section 48 Access Doors and Panels
(2)
12-12-01/301, Hydraulic Systems
(3)
24-22-00/201, Manual Control
(4)
27-23-00/501, Rudder and Elevator Hydraulic Shutoff Valve
(5)
29-11-00/201, Main Hydraulic Supply System
D.
Access
(1)
Location Zone
311 Area Aft of Pressure Bulkhead, LH
312 Area Aft of Pressure Bulkhead, RH
(2)
Access Panel 312A Horizontal Stabilizer Jackscrew Access Door
E.
Procedure
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-23-01
ALL ú ú 01 Page 404 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 114-037
WARNING:_______ DO NOT GET SOLVENTS IN YOUR MOUTH, OR YOUR EYES, OR ON YOUR
SKIN. DO NOT BREATHE THE FUMES FROM SOLVENTS. SOLVENTS ARE
HAZARDOUS MATERIALS. SOLVENTS MAY BE FLAMMABLE OR HARMFUL TO
THE ENVIRONMENT. REFER TO PRODUCT MATERIAL SAFETY DATA SHEETS
(MSDS) AND LOCAL REQUIREMENTS FOR PROPER HANDLING PROCEDURES.
(1)
Clean the mating surfaces of the bracket (10) and the shutoff valve
(4)
with solvent, Series 82 (AMM 20-30-82).
S 424-011
(2)
Do these steps to install the shutoff valve.
(a)
Put the shutoff valve (4) in its position.
(b)
Install the two bolts (3), washers (2), and nuts (1) that attach the shutoff valve to the bracket (10).
(c)
Install the bolt (3) for the hydraulic line support (9), the washer (2), and the nut (1). 1) Tighten the nut (1) to 50-70 pound-inches.
(d)
Remove the caps from the hydraulic lines and the ports.
(e)
Apply some assembly lube to the hydraulic fittings.
(f)
Install the packings (5 and 7), the O-ring (6), and the adapter
(8)
in the shutoff valve.
(g)
Connect the hydraulic lines to the shutoff valve.
(h)
Connect the electrical connectors to the shutoff valve.
1) Hydraulic system No. 1: DV142A DV142B
2) Hydraulic system No. 2: DV143A DV143B
3) Hydraulic system No. 3: DV147A DV147B
4) Hydraulic system No. 4: DV150A DV150B
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-23-01
ALL ú ú 01 Page 405 ú Jun 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 714-036
(3)
Do a test of the shutoff valve (Ref 27-23-00/501).
S 794-023 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 2(164)