(3)
24-22-00/201, Manual Control
(4)
29-11-00/201, Main Hydraulic Supply System
(5)
IPC 27-23-01 Fig. 1
C.
Access
(1)
Location Zone
311 Area Aft of Pressure Bulkhead, LH
312 Area Aft of Pressure Bulkhead, RH
(2)
Access Panel 312A Horizontal Stabilizer Jackscrew Access Door
D.
Prepare for the Removal
(1)
Supply electrical power (Ref 24-22-00/201).
S 864-003
(2)
Find the switches for the FLT CONTROL HYD POWER on the pilot's overhead maintenance panel, P461.
(a)
Put the four TAIL switches in the SHUTOFF position.
S 864-002
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-23-01
ALL ú ú 01 Page 401 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SEE A HORIZONTAL STABILIZER
3 JACKSCREW
SEE 4 A SEE 1 A
SEE 2 A
1. NUT (2) 2. WASHER (2) 3. BOLT (2)
10. BRACKET
9. HYDRAULIC LINE SUPPORT 4. SHUTOFF VALVE
1. NUT ELECTRICAL CONNECTORS
5. PACKING
3. BOLT 2. WASHER 6. O-RING 7. PACKING
8. ADAPTER
HYDRAULIC LINES
SHUTOFF VALVE (EXAMPLE)
1 2 3 4 INBOARD ELEVATOR THAT USE HYDRAULIC SYSTEM NO. 2. AND LEFT INBOARD ELEVATORS THAT USE HYDRAULIC AND RIGHT INBOARD ELEVATORS THAT USE SHUTOFF VALVE FOR THE LOWER RUDDER, RIGHT OUTBOARD INBOARD ELEVATOR THAT USE HYDRAULIC SYSTEM NO. 3. SHUTOFF VALVE FOR THE UPPER RUDDER AND RIGHT SHUTOFF VALVE FOR THE LOWER RUDDER AND LEFT SHUTOFF VALVE FOR THE UPPER RUDDER, LEFT OUTBOARD SYSTEM NO. 1. HYDRAULIC SYSTEM NO. 4. A
Shutoff Valve Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-23-01
ALL ú ú 01 Page 402 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 864-005
(3)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a)
P180, DC Power Distribution Panel
1) 180H8 ELEV/RUD VLV SYS 1
2) 180E7 ELEV/RUD VLV SYS 2
3) 180H23 ELEV/RUD VLV SYS 3
4) 180E22 ELEV/RUD VLV SYS 4
S 864-006
(4)
Remove pressure from the applicable hydraulic system
(Ref 29-11-00/201).
S 014-007
(5)
Open the access door, 312A, for the stabilizer jackscrew
compartment.
E.
Procedure
S 034-030
(1)
Disconnect the electrical connectors from the applicable shutoff valve.
(a)
Hydraulic system No. 1:
1) DV142A
2) DV142B
(b)
Hydraulic system No. 2:
1) DV143A
2) DV143B
(c)
Hydraulic system No. 3:
1) DV147A
2) DV147B
(d)
Hydraulic system No. 4:
1) DV150A
2) DV150B
S 034-031
(2) Disconnect the hydraulic lines from the shutoff valve.
NOTE: Use a bucket to catch the hydraulic fluid from the
____
hydraulic lines.
S 034-032
(3)
Put caps on the hydraulic lines and ports.
S 024-033
(4)
Remove the two bolts (3), washers (2), and nuts (1) that attach the shutoff valve (4) to the bracket (10).
S 024-034
(5)
Remove the bolt (3), the washer (2), and the nut (1) from the hydraulic line support (9).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-23-01 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 2(163)