ESCAPE SLIDE GAS SUPPLY HOSE CHUTE ENTRY DOORWAY BOTTLE STORED GAS
GIRT ESCAPE SLIDE
SWIVEL FITTING
SHROUD
ESCAPE SLIDE DEPLOYED
Escape Slide Operation
Figure 2 (Sheet 1)
RAMP PLATE
FLOOR RAMP
FWD INBD
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
25-68-00
ALL ú CONFIG 2 ú 02 Page 6 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
B40487
A
747-400 MAINTENANCE MANUAL
ESCAPE ASSEMBLYSLIDE IN (OVERBOARDING)PACK GAS DEPLOYMENT POSITIONPACKBOARD SUPPLY
(POSITION PRIOR HOSE
TO DEPLOYMENT) FLIGHT COMPARTMENTCHUTE ENTRY DOOR THRESHOLD
TORQUE TUBE
(PIVOT POINT)
PACKBOARD RETAINING GIRT
DEPLOYMENT SEQUENCE
Escape Slide Operation
Figure 2 (Sheet 2)
SLIDE
DEPLOYING
PACKBOARD
PACKBOARD ANCHORED TO FUSELAGE AND SLIDE INFLATES
FUSELAGE
B40490
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
25-68-00
ALL ú CONFIG 2 ú 02 Page 7 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
(7)
The escape slide turbine pumps are driven by the stored gas bottle gas flow and induce ambient air into the escape slide. The induction of ambient air occurs in two pumping stages: the first stage for high volume induction at low pressure, the second stage at lower volume induction against the increasing back pressure of the air and gas in the escape slide. As the pressure of the stored gas bottle decays, check valves close to maintain slide pressure. Inflation of the escape slide is completed approximately 5 seconds after stored gas bottle gas flow release.
(8)
The slide does not deploy completely to reach the ground, until inflation has built up enough pressure to apply sufficient tension on the slide retaining straps. This ensures the slide will be rigid enough to oppose nominal wind forces and keep the slide deployed to align with the doorway.
(9)
The slide girt is retained at the doorway by a girt bar inserted in the girt fold and locked in the chute channel.
(10)
As the chute rotates to rest on the doorway threshold a ramp plate is raised from the base assembly platform to align with the inboard edge of the chute and provide a level walkway to the door opening.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
25-68-00
ALL ú CONFIG 2 ú 02 Page 8 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 FAULT ISOLATION/MAINT MANUAL
FLOOR-MOUNTED ESCAPE SLIDE
COMPONENT SHT 102 FIG. QTY X ACCESS/AREA REFERENCE
CABLE - INFLATION TRIGGER BOTTLE - STORED GAS PACK - FLOOR-MOUNTED ESCAPE SLIDE HANDLE - MANUAL INFLATION 1 1 1 1 1 1 1 1 STORED GAS BOTTLE ESCAPE SLIDE PACK PART OF STORED GAS BOTTLE BETWEEN ESCAPE SLIDE PACK AND INBOARD OF UPPER DECK DOOR PART OF EACH FLOOR-MOUNTED 25-68-00 25-68-00 25-68-00 25-68-02
Floor-Mounted Escape Slide - Component Index
Figure 101
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú 25-68-00
ALL ú CONFIG 2 ú 02 Page 101 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
C08318
A
747-400 FAULT ISOLATION/MAINT MANUAL
SEE A
SEE B
FLOOR-MOUNTED
ESCAPE SLIDE
UPPER DECK COMPARTMENT RUBBER
PADS
ESCAPE SLIDE PACK
SEE B
INFLATION
TRIGGERING
CABLE
SHROUD
PACKBOARD CHUTE ESCAPE SLIDE
EXTENSION PANEL GAS SUPPLY HOSE
GIRT BAR RETAINER CHANNEL
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 EQUIPMENT/FURNISHINGS 2(160)