73-21-12
ALL ú ú C02 Page 401 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////
A
Power Management Control Panel Location
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
73-21-12
ALL ú
ú C01 Page 402
ú Mar 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////
S 434-016-C00
CAUTION: CROSS CONNECTION OF THE PMC PANEL (ON THE P5 OVERHEAD PANEL) IS
_______ A POSSIBILITY WHEN WORKING WITH THIS COMPONENT. POSITIVELY IDENTIFY CONNECTIONS BEFORE CONNECTING AND FUNCTION CHECK UPON COMPLETION OF CONNECTION.
(1)
Connect the electrical connectors to the control panel.
S 424-006-C00
(2)
Install the PMC panel in the aft overhead panel.
NOTE: Attach the panel with fasteners (four locations).
____
S 864-007-C00
(3) Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a) P6-2 Load Control Center
1) ENGINES MASTER CAUTION
S 714-008-C00
(4) Put the PMC ON/INOP switch on the control panel in the off position.
(a) Make sure that the PMC INOP warning light is on.
S 714-009-C00
(5) Move the PMC ON/INOP switch to the ON position.
(a) Make sure that the PMC INOP warning light goes off.
S 864-010-C00
(6)
Move the PMC ON/INOP switch to the off position.
S 714-012-C00
(7)
Do the Master Caution Dim Test for the Reverser (AMM 33-15-00/501).
S 714-013-C00
(8)
Do the Master Caution Dim Test for the Low Idle lights (AMM 33-15-00/501).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn