• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 16:42来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 31-24-52
 ú ú 03 Page 402 ú Mar 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 434-018
 (7)  
Install the cables (Fig. 401).

 (a)  
Install cable C between the sensor quadrant on the upper surface of the elevator forward quadrant shaft and the sensor pulley drum.

 (b)  
With the cable terminals attached to the quadrant and pulley drum, attach the cable terminals with the cotter pins (Fig. 402).

 (c)  
Attach the ball terminal end of cable A to the lower quadrant on the elevator forward quadrant shaft.

 (d)  
Attach the ball terminal end of cable B to the pully drum on the sensor.

 (e)  
Connect the spring between the loose end terminals of cables B and A.

 (f)  
Lubricate the cables with grease for the full length of travel on the drum and quadrant.

 (g)  
Loosen the mounting bolts on the sensor support bracket.

 (h)  
Move the bracket in the slots on the right angle bracket to align the cables.

 (i)  
AIRPLANES WITHOUT SERVICE LETTER 737-SL-27-089-A; Make sure the dimension across the spring between the cable terminals is 2.09 |0.02 inches (Fig. 401).

 (j)  
AIRPLANES WITH SERVICE LETTER 737-SL-27-089-A; Make sure the dimension across the spring between the cable terminals is 2.03 |0.02 inches (Fig. 401).

 (k)  
Remove the laminations from the laminated shim to get the correct dimension.

 

 (10)
 Hold the cable drum and turn the sensor until the mark on the shaft aligns with the mark on the sensor.


 (8)  S 434-019Tighten the four bolts on the sensor support bracket.
 (9)  S 034-020Loosen the two sensor clamp screws.
 S 824-021

 NOTE: No special position of the aligned marks is necessary.
____
 S 434-022
 (11)
 Tighten the clamp screws to 30-35 lb-in.

 S 434-023

 (12)
 Install the electrical connector on the sensor.

 S 034-024

 (13)
 Remove the rigging pin.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. B-2535 AND ON ú

 31-24-52
 ú ú 09 Page 403 ú Mar 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 414-025
 (14)
 Close the forward access door, 1103.

 S 714-026

 (15)
 Do this task: Control Column Position Sensor Test (Ref 31-24-52/501).


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. B-2535 AND ON ú

 31-24-52
 ú ú 09 Page 404 ú Mar 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

737-300/400/500
MAINTENANCE MANUAL

SENSOR
LEFT
CABLE
COLUMN
QUADRANT
PULLEY
DRUM

SENSOR CABLE QUADRANT
SENSOR CLAMP SCREW (2 LOCATIONS)
SENSOR FWD
SEE A
SUPPORT
BRACKET BOLT

ELEVATOR QUADRANT
ELECTRICAL CONNECTOR
SENSOR CABLE
SENSOR QUADRANT
SUPPORT
BRACKET
SENSOR

CABLE C ELEVATORSHIM
FORWARD QUADRANT
SENSOR CABLE CABLE B
QUADRANT
2.09 |0.02
CABLE A
INCHES
FWD
A

Control Column Position Sensor Installation
Figure 401 (Sheet 1)

F00702
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT SERVICE LETTER ú

 31-24-52
 737-SL-27-089-A  ú ú 09 Page 405 ú Jul 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

737-300/400/500
MAINTENANCE MANUAL

SENSOR
LEFT
CABLE
COLUMN
QUADRANT
PULLEY
DRUM

SENSOR CABLE QUADRANT
SENSOR CLAMP SCREW (2 LOCATIONS)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 仪表 INSTRUMENTS(112)