(h)
Make sure that the SMC 1 display shows DADC #1 INACTIVE.
(i)
Make sure that the SMC 2 display shows DADC #2 INACTIVE.
(j)
Close the AIR DATA CMPTR 1 AC circuit breaker on the P18-2 panel and the AIR DATA CMPTR 2 AC circuit breaker on the P6-1 panel.
S 745-077-002
(2)
Do a check of the IRU input to the SMC:
(a)
Make sure that the IRS L and IRS R switches on the IRS mode select unit (P5 overhead panel) are not in the OFF position.
___
(b)
Push each down button.
(c)
Make sure that each display shows IRU ACTIVE.
(d)
Open these circuit breakers:
1) P6 Panel
a) IRS NO. 2 AC
b) IRS NO. 2 DC
2) P18 Panel
a) IRS NO. 1 AC
b) IRS NO. 1 DC
(e)
Make sure that the SMC 1 display shows IRU #1 INACTIVE.
(f)
Make sure that the SMC 2 display shows IRU #2 INACTIVE.
(g)
Close these circuit breakers:
1) P6 Panel
a) IRS NO. 2 AC
b) IRS NO. 2 DC
2) P18 Panel
a) IRS NO. 1 AC
b) IRS NO. 1 DC
S 745-060-002
(3) AIRPLANES WITH A SINGLE FMC INSTALLED; Do a check of the FMC input to the SMC:
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH STALL MANAGEMENT ú
27-32-00
COMPUTER P/N 65-52822 ú CONFIG 2 ú 10 Page 507 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(a)
Push each down button.
(b)
Make sure that each display shows FMC ACTIVE.
S 745-062-002
(4)
AIRPLANES WITH DUAL FMC INSTALLED; Do a check of the FMC input to the SMC:
(a)
Set the FMC transfer switch on the P5-28 panel to the "NORMAL" position.
(b)
Push each down button.
(c)
Make sure each display shows FMC ACTIVE.
(d)
Open this circuit breaker on the P18-2 panel:
1) FMCS CMPTR NO. 1
(e)
Make sure the display on SMC1 shows FMC INACTIVE.
(f)
Open this circuit breaker on the P6-1 panel:
1) FMCS CMTR NO. 2
(g)
Make sure the display on SMC2 shows FMC INACTIVE.
(h)
Close this circuit breaker on the P18-2 panel:
1) FMCS CMPTR NO. 1
(i)
Close this circuit breaker on the P6-1 panel:
1) FMCS CMPTR NO. 2
(j)
Set the FMC transfer switch on the P5-28 panel to "BOTH ON R" position.
(k)
Make sure each SMC display shows FMC ACTIVE.
(l)
Open this circuit breaker on the P6-1 panel:
1) FMCS CMPTR NO. 2
(m)
Make sure each SMC display shows FMC INACTIVE.
(n)
Close this circuit breaker on the P6-1 panel:
1) FMCS CMPTR NO. 2
(o)
Set the FMC transfer switch on the P5-28 panel to "BOTH ON L" position.
(p)
Make sure each SMC display shows FMC ACTIVE.
(q)
Open this circuit breaker on the P18-2 panel:
1) FMCS CMPTR NO. 1
(r)
Make sure each SMC display shows FMC INACTIVE
(s)
Close this circuit breaker on the P18-2 panel:
1) FMCS CMPTR NO. 1
(t)
Set the FMC transfer switch on the P5-28 panel to the "NORMAL" position.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH STALL MANAGEMENT ú
27-32-00
COMPUTER P/N 65-52822 ú CONFIG 2 ú 07 Page 508 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 3(53)