| | A/S VALV | SMC 1 | Check and repair circuit between connector D2771A pin 5| | FAIL | | at SMC 1 M1506 and connector D3188 pin 1 at the autoslat| | | | valve V132 (WDM 27-83-11). If the problem continues,| | | | replace the SMC 1 solenoid on the autoslat valve V132| | | | (MM 27-83-31/401).| .................................................................................| | |
| | A/S VALV | SMC 2 | Check and repair circuit between connector D2773A pin 5| | FAIL | | at SMC 2 M1507 and connector D3190 pin 1 at the autoslat| | | | valve V132 (WDM 27-83-21). If the problem continues,| | | | replace the SMC 2 solenoid on the autoslat valve V132| | | | (MM 27-83-31/401).| | | | | | | | | | | | | | | | | | | | | | | | | 2...........….......…...........................................................1
 STALL MANAGEMENT COMPUTER FAULT INDEX

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH STALL MANAGEMENT ú

 27-32-00
 COMPUTER P/N 65-52822  ú CONFIG 2 ú 02 Page 112 ú Mar 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 ~............................................................................... | SMC FAULT | FROM | CORRECTIVE ACTION | .................................................................................| | |
| | AIR/GND | SMC 1 | Go to the GROUND TEST? menu on SMC 1 and select the| | INACTIVE | | DISCRETE INPUTS? menu. Go to the AIR/GND display.| | | | A. Push the AIR SENSING test switch on the E-11 shelf and| | | | make sure that the SMC display reads AIR GND AIR. If| | | | the display does not read AIR GND AIR, replace air| | | | sensing relay R276 (WDM 32-31-11).| | | | B. Push the GND SENSING test switch on the E-11 shelf and| | | | make sure that the SMC display reads AIR GND AIR. If| | | | the display does not read AIR GND AIR, replace ground| | | | sensing relay R277 (WDM 32.31.12).| | | | If the problem continues, check and repair circuit| | | | between connector D2596 pin 35 at the E-11 shelf and| | | | connector 2771B pin 31 at SMC 1 M1506; and check and| | | | repair circuit between connector D2796 pin 15 at the E-11| | | | shelf and connector 2771B pin 21 at SMC 1 M1506| | | | (WDM 27-32-12).| .................................................................................| | |
| | AIR/GND | SMC 2 | Go to the GROUND TEST? menu on SMC 2 and select the| | INACTIVE | | DISCRETE INPUTS? menu. Go to the AIR/GND display.| | | | A. Push the AIR SENSING test switch on the E-11 shelf and| | | | make sure that the SMC display reads AIR GND AIR. If| | | | the display does not read AIR GND AIR, replace air| | | | sensing relay R280 (WDM 32-31-11).| | | | B. Push the GND SENSING test switch on the E-11 shelf and| | | | make sure that the SMC display reads AIR GND AIR. If| | | | the display does not read AIR GND AIR, replace ground| | | | sensing relay R343 (WDM 32-31-12).| | | | If the problem continues, check and repair circuit| | | | between connector D2596 pin 45 at the E-11 shelf and| | | | connector 2773B pin 31 at SMC 2 M1507; and check and| | | | repair circuit between connector D2794 pin 36 at the E-11| | | | shelf and connector 2773B pin 21 at SMC 2 M1507| | | | (WDM 27-32-22).| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2...........….......…...........................................................1
 STALL MANAGEMENT COMPUTER FAULT INDEX

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH STALL MANAGEMENT ú

 27-32-00
 COMPUTER P/N 65-52822  ú CONFIG 2 ú 02 Page 113 ú Mar 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 ~............................................................................... | SMC FAULT | FROM | CORRECTIVE ACTION | .................................................................................| | |
| | AIR/GND | SMC 1 | Go to the GROUND TEST? menu on SMC 1 and select the| | INVALID | | DISCRETE INPUTS? menu. Go to the AIR/GND display.| | | | A. Push the AIR SENSING test switch on the E-11 shelf and| | | | make sure that the SMC display reads AIR GND AIR. If| | | | the display does not read AIR GND AIR, replace air| | | | sensing relay R276 (WDM 32-31-11).| | | | B. Push the GND SENSING test switch on the E-11 shelf and| | | | make sure that the SMC display reads AIR GND AIR. If| | | | the display does not read AIR GND AIR, replace ground| | | | sensing relay R277 (WDM 32.31.12).| | | | If the problem continues, check and repair circuit| | | | between connector D2596 pin 35 at the E-11 shelf and| | | | connector 2771B pin 31 at SMC 1 M1506; and check and| | | | repair circuit between connector D2796 pin 15 at the E-11| | | | shelf and connector 2771B pin 21 at SMC 1 M1506| | | | (WDM 27-32-12).| .................................................................................| | |
 