• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 19:20来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 101, 102  Control Cabin
 205  Electronic Compartment
 502, 503  Fan Cowl, Left Engine
 602, 603  Fan Cowl, Right Engine
 (2)  Access Panels
 1201  Electronic Equipment Access Door
 5737  Right Fan Cowl Assembly, Left Engine
 5746  Left Fan Cowl Assembly, Left Engine
 5837  Right Fan Cowl Assembly, Right Engine
 5846  Left Fan Cowl Assembly, Right Engine

Preparation for the Test
 S 865-001-001
 (1)  
Supply electrical power (Ref 24-22-00/201).

 S 865-002-001

 (2)  
Open these circuit breakers:

 (a)  
P6 Panel 1) AUTOSLAT 1 AC 2) AUTOSLAT NO. 1 DC 3) AUTOSLAT 2 AC 4) AUTOSLAT NO. 2 DC

 (b)  
P18 Panel 1) STALL WARN ASYM MODE


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH DIGITAL STALL WARNING ú

 27-32-00
 COMPUTER P/N 65-52819  ú CONFIG 1 ú 02 Page 502 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 F. BITE Test
 S 075-006-001
 (1)  
Erase the stall warning computer No. 1 fault memory:

 (a)  
Push and hold the START BITE switch on the front of stall warning computer No. 1.

 (b)  
Make sure that all lights on the computer come on for 2 to 4 seconds.

 (c)  
Look to see if one or more lights stays on after 4 seconds.


 NOTE: If a light stays on after 4 seconds, the computer
____ memory holds a failure for that function. The light will go off after approximately 25 seconds.
 (d)  When one or more light starts to flash after 10 to 20 seconds, release the START BITE switch. The memory is now clear.
 S 075-007-001
 (2)  
Erase the stall warning computer No. 2 fault memory:

 (a)  
Push and hold the START BITE switch on the front of stall warning computer No. 2.

 (b)  
Make sure that all lights on the computer come on for 2 to 4 seconds.

 (c)  
Look to see if one or more lights stays on after 4 seconds.


 NOTE: If a light stays on after 4 seconds, the computer
____ memory holds a failure for that function. The light will go off after approximately 25 seconds.
 (d)  When one or more light starts to flash after 10 to 20 seconds, release the START BITE switch. The memory is now clear.
 S 745-003-001
 (3)  
Do a BITE test for stall warning computer No. 1:

 (a)  
Push and hold the START BITE switch on the front of stall warning computer No. 1.

 (b)  
Make sure that all lights on the computer come on for 2 to 4 seconds.

 (c)  
Release the START BITE switch.

 (d)  
Look to see if one or more light stays on after 4 seconds.


 NOTE: If a light stays on after 4 seconds, the computer
____ memory holds a real-time failure for that function.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH DIGITAL STALL WARNING ú

 27-32-00
 COMPUTER P/N 65-52819  ú CONFIG 1 ú 01 Page 503 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 745-004-001
 (4)  
Do a BITE test for stall warning computer No. 2:

 (a)  
Push and hold the START BITE switch on the front of stall warning computer No. 2.

 (b)  
Make sure that all lights on the computer come on for 2 to 4 seconds.

 (c)  
Release the START BITE switch.

 (d)  
Look to see if one or more light stays on after 4 seconds.


 NOTE: If a light stays on after 4 seconds, the computer
____ memory holds a real-time failure for that function.
 G. Stall Warning Operation Test
 S 715-005-001
 (1)  
Do a test of the stall warning system No. 1 operation:

 (a)  
Push and hold the STALL WARNING TEST NO. 1 switch on the stall warning test module (P5 overhead panel).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 3(41)