 on the|  |  |  VSCF FAULT DETECTED |  |
 annunciator|  |  |  light. |  |
 | panel comes  |  |  |  |
 | on.  |  |  |  |
 |  |  |  |  |
 | Also,  |  |  |  |
 |  |  |  |  |
 |  |  The CT has a  |  Examine the continuity  |  Replace the |
 |  |  defect, or the  |  of the CTs and thier  |  CT or repair |
 |  |  wiring is not  |  wires (WDM 24-23-11,  |  the wiring. |
 |  |  correct to the  |  or WDM 24-23-21). |  |
 |  |  differential |  |  |
 |  |  protection |  |  |
 |  |  current |  |  |
 |  |  transformers |  |  |
 |  |  (in load |  |  |
 |  |  control center). |  |  |
 |  |  |  |  |
 |  |  The CT has a  |  Examine the continuity  |  Replace the |
 |  |  defect, or the  |  of the CTs and thier  |  CT or repair |
 |  |  wiring is not  |  wires (WDM 24-21-11,  |  the wiring. |
 |  |  correct to the  |  or WDM 24-23-11 and |  |
 |  |  generator  |  WDM 24-28-31). |  |
 |  |  neutral current |  |  |
 |  |  transformer (CT) |  |  |
 |  |  (on the side of |  |  |
 |  |  the engine). |  |  |
 |  |  |  |  |
 |  |  |  |  |
 |  |  A short or a  |  The GCR trips and  |  Repair the |
 |  |  ground fault on  |  then the GCB trips.  |  damaged wires |
 |  |  the generator  |  |  or replace the|
 |  |  output wires  |  |  damaged parts |
 |  |  in the |  |  |
 |  |  differential |  |  |
 |  |  protection zone |  |  |
 |  |  |  |  |

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-21-00
 ALL  ú ú 02 Page 104 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 ~.............................................................................. | TROUBLE | PROBABLE CAUSE | ISOLATION PROCEDURE | REMEDY | ................................................................................
 |  the GCR and  |  The main power  |  Do the BITE test for the  |  Repair the |
 |  the GCB trip.|  wire have an  |  VSCF. Look for the  |  circuit in the|
 |  |  open circuit.  |  AIRCRAFT OPEN PHASE  |  power wires |
 |  |  |  DETECTED light.  |  between the |
 |  |  |  |  VSCF and the |
 |  |  |  |  main ac bus. |
 |  |  |  |  Replace the |
 |  |  |  |  GCB if it is |
 |  |  |  |  necessary |
 |  |  |  |  (WDM 24-21-11,|
 |  |  |  |  WDM 24-21-21, |
 |  |  |  |  WDM 24-22-31, |
 |  |  |  |  WDM 24-51-11, |
 |  |  |  |  and |
 |  |  |  |  WDM 24-51-21).|
 |  |  |  |  |
 |  |  An overcurrent  |  Examine the generator  |  Replace the |
 |  |  fault condition.  |  feeder wires and the  |  defective |
 |  |  |  loads on the wires for  |  parts or |
 |  |  |  defects.  |  repair the |
 |  |  |  |  wires. |
 |  |  |  |  |
 |  |  The over current  |  Examine the circuit with  |  Replace the |
 