YES YES
1 MAKE SURE THAT THE ENGINES
21 DO THE LEAK CHECK OF THE
ARE SHUT DOWN FOR 5 MINUTES OIL SYSTEM OF THE AC GENERATOR
MINIMUM. REMOVE THE VENT PLUG DRIVE (AMM 24-11-00/201).
AND EXAMINE THE OIL LEVEL IN DID YOU FIND LEAK(S) IN
THE SIGHT GLASS OF THE VSCF. PARTS OF THE OIL SYSTEM THAT
IS THE OIL LEVEL BELOW THE ARE EXTERNAL TO THE VSCF? "ADD" LINE?NO NO
NO
2 INSTALL THE VENT PLUG.
43 RECONNECT D6. REPLACE THE
DISCONNECT CONNECTOR D6 FROM P5-5 MODULE (WDM 24-11-11).
THE VSCF. IF THE PROBLEM CONTINUES, DOES THE DRIVE OR LOW OIL THEN FOR ENGINE 1 (ENGINE 2),
PRESSURE LIGHT GO OFF?EXAMINE THE CIRCUIT FROM CON-NECTOR D6, PIN 7, TO THE VSCF,YES
AND CONNECTOR D1086, PIN 7
(CONNECTOR D636, PIN 33), TO
SEE SHEET 2 THE P5-5 MODULE (WDM 24-11-11,
(BLOCK 3) -12).
REPAIR THE PROBLEMS THAT YOU FIND.
The DRIVE or LOW OIL PRESSURE Light Stays On at Engine Speeds More Than 40% N2
Figure 101 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. VARIABLE SPEED CONSTANT FREQUENCY ú
24-11-00
GENERATOR/CONVERTERS ú CONFIG 2 ú 02 Page 102 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
B06359
FROM SHEET 1 (BLOCK 2) YES
YES
4 DO THE USUAL ENGINE SHUT-
DOWN PROCEDURE (AMM 71-00-00/
201). REMOVE THE FILTER ELE-
MENT FROM THE FILTER IN THE
GENERATOR DRIVE OIL LINE
(AMM 24-11-31/201). EXAMINE
THE FILTER FOR LARGE METAL
PARTICLES.
DOES THE FILTER ELEMENT CONTAIN LARGE METAL PARTICLES?
NO
A 737-300/400/500MAINTENANCE MANUAL
NO
YES
44 DO THE USUAL ENGINE SHUT-DOWN PROCEDURE (AMM 71-00-00/ 201). REPLACE THE VSCF (AMM 24-11-11/401).
45 REPLACE THE VSCF (AMM 24-11-11/401) AND THE OIL COOLER (AMM 24-11-21/401). REPLACE TUBING FOR THE OIL COOLER.
B06361
The DRIVE or LOW OIL PRESSURE Light Stays On at Engine Speeds More Than 40% N2
Figure 101 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. VARIABLE SPEED CONSTANT FREQUENCY ú
24-11-00
GENERATOR/CONVERTERS ú CONFIG 2 ú 02 Page 103 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
PREREQUISITES
ELECTRICAL POWER (24-22-00/201) ENGINES SHUT DOWN
THE HIGH OIL TEMP
CBs: C446 CSD CONT-1 LIGHT COMES ON C467 CSD CONT-2
NO
1
EXAMINE THE AIR PASSAGES
OF THE EXTERNAL VSCF OIL
COOLER.
ARE THE AIR PASSAGES CLEAR?
YES
NO
2 MAKE SURE THAT THE ENGINES
ARE SHUT DOWN FOR 5 MINUTES
MINIMUM. REMOVE THE VENT PLUG
AND EXAMINE THE OIL LEVEL IN
THE SIGHT GLASS OF THE VSCF.
IS THE OIL LEVEL BETWEEN THE "FULL" LINE AND THE "ADD"LINE?
YES