(f)
Do a check of the APU generator voltage output. 1) Set the AC meter selector switch on the forward overhead panel P5-13 to APU GEN. 2) Momentarily set the two APU GEN switches on the P5-4 panel
to ON. 3) Make sure that the APU GEN OFF BUS light goes off. 4) Make sure the AC voltmeter shows 110 to 125 volts and the
CPS FREQ meter shows 397-417 Hz.
(g) Put the airplane back in its usual condition. 1) Stop the APU (AMM 49-11-00/201).
TASK 24-21-21-004-094
4. APU Generator Removal (APU Removed) (Fig. 401)
___________________________________
A. References
(1) AMM 49-11-00/401, APU Power Plant
B. Access
(1)
Location Zone
303 APU Compartment
(2)
Access Panel
3804 APU Cowl Panel
C. Procedure
S 014-024
(1) Remove the APU (AMM 49-11-00/401), if you did not do this before.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-21
ALL ú ú 03 Page 408 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
GENERATOR
GENERATOR
SEEA
SEE B
TERMINAL
COVER SCREW
(4 PLACES)
GENERATOR OUTPUT CONNECTOR
CONTROL
GENERATOR CONNECTOR
TERMINALS
B1
B2
B3
EXCITER TERMINALS
(COVER REMOVED)
CURRENT TRANSFORMER MOUNT ASSEMBLY
DUCT SUPPORT BRACKET
GROUND BUS BAR ANGLE
DIFFERENTIAL CURRENT TRANSFORMER
GROUND LEAD
DIFFERENTIAL CURRENT TRANSFORMER CONNECTOR
FWD
____COOLING AIR CROSSOVER DUCT OMITTED.
NOTE:
APU AC Generator Installation Figure 401 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH FORWARD ROUTING OF ú
24-21-21
THE APU GENERATOR FEEDER CABLES ú
(BEFORE SB 1076) ú 01 Page 409 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
SEE A
GENERATOR
AC GENERATOR TERMINALS
EXCITER TERMINALS
(COVER REMOVED)
CURRENT
TRANSFORMER
MOUNT ASSEMBLY
DUCT SUPPORT
BRACKET
B1
B2 BAR ANGLE GROUND BUS
SEE B B3 CURRENT DIFFERENTIAL
TRANSFORMER
TERMINAL GROUND
COVER SCREW LEAD
(4 PLACES)
DIFFERENTIAL
CURRENT
TRANSFORMER
CONNECTOR
GENERATOR GENERATOR
OUTPUT CONTROL
CONNECTOR CONNECTOR
NOTE:COOLING AIR CROSSOVER DUCT OMITTED.
APU AC Generator Installation
Figure 401 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH AFT ROUTING OF ú
24-21-21
THE APU GENERATOR FEEDER CABLES ú
(AFTER SB 1076) ú 01 Page 410 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
ELECTRICAL CONNECTOR A 737-300/400/500MAINTENANCE MANUAL COOLING AIR CROSSOVER DUCT AFT DUCT CLAMP (LEFT SIDE)
OF GENERATOR) (FORWARD END MOUNTING BOLT CROSSOVER DUCT
FUEL LINE
OVERTEMPERATURE CONTROL SWITCH
COOLER FWD
A FORWARD AND AFT APU COOLER CLAMPS GENERATOR
MOUNTING FLANGE APU GENERATOR (12 LOCATIONS) APU GENERATOR MOUNTING NUTS AND STUDS
INDEX MARK APU AND GENERATOR FLANGES; TO CORRECTLY CLOCK-POSITION GENERATOR AT INSTALLATION
B FWD
Figure 401 (Sheet 3) APU AC Generator Installation