(b)
Set the right switch to the 1 position.
(c)
Connect a connector to each of the DC jacks.
(d)
Attach the black lead of the rotor fault indicator to the DC-connection.
(e)
Attach the red lead of the rotor fault indicator to the DC+ connection.
F. Do a Test on the Generator Rotating Rectifier
S 716-031
(1) ENGINES WITH A CSD;
Do a Test of the Engine No. 1 Generator.
(a)
Set the left switch on the M400 module to the A position.
(b)
Set the switch S1 on the rotor fault indicator to the DS1 MUST BE ON position. 1) Make sure that the DS1 light on the rotor fault indicator
comes on.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-61
ALL ú ú 03 Page 602 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(c) Set the switch S1 on the rotor fault indicator to the DS1 MUST GO OFF position. 1) Make sure that the DS1 light comes on.
NOTE: The DS1 light can flash momentarily when you move
____
the switch S1.
2) If the DS1 light does not show the correct indications, do one of these steps: a) Repair the connection of the wires to the generator
field terminals.
b) Replace the generator.
(d) Release the S1 switch and permit the switch to go back to the OFF position.
S 866-036
(2) ENGINES WITH A CSD; Do a Test of the Engine No. 2 Generator.
(a)
Set the left switch on the M400 module to the B position.
(b)
Set the switch S1 on the rotor fault indicator to the DS1 MUST BE ON position. 1) Make sure that the DS1 light on the rotor fault indicator
comes on.
(c)
Set the switch S1 on the rotor fault indicator to the DS1 MUST GO OFF position. 1) Make sure that the DS1 light comes on.
NOTE: The DS1 light can flash momentarily when you move
____
the switch S1.
2) If the DS1 light does not show the correct indications, do one of these steps: a) Repair the connection of the wires to the generator
field terminals.
b) Replace the generator.
(d) Release the S1 switch and permit the switch to go back to the OFF position.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-61
ALL ú ú 03 Page 603 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 866-019
(3) Do a test of the APU generator.
(a)
Set the left switch on the M400 module to the C position.
(b)
Set the switch S1 on the rotor fault indicator to the DS1 MUST BE ON position. 1) Make sure that the DS1 light on the rotor fault indicator
comes on.
(c)
Set the switch S1 on the rotor fault indicator to the DS1 MUST GO OFF position. 1) Make sure that the DS1 light comes on.
NOTE: The DS1 light can flash momentarily when you move
____
the switch S1.
2) If the DS1 light does not show the correct indications, do one of these steps: a) Repair the connection of the wires to the generator
field terminals. b) Replace the generator.
(d) Release the S1 switch and permit the switch to go back to the OFF position.
G. Put the Airplane in Its Usual Condition
S 866-020
(1)
Set the left switch on the M400 module to the H position.
S 866-021
(2)
Disconnect the leads for the rotor fault indicator from the M400 module.
S 866-022
(3)
Disconnect the rotor fault indicator connectors from the M400 module.
(4)
Stop the APU (AMM 49-11-00/201).
S 866-023
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 电源 ELECTRICAL POWER(121)