close time. From the ground, measure the time for
the door to close. Start to measure the time as
soon as the doors start to close.
(e) Move the landing gear lever to the UP position.
1) Make sure that the gear is up and locked.
a) Make sure the components attached to the landing gear
do not interfere with the landing gear as it retracts.
(f) Move the landing gear control lever to the OFF position.
(g) Move the landing gear control lever to the "DN" position and
then move the landing gear control lever to the "UP" position
uniformly over a period of approximately 3 seconds when the
landing gear is half way down.
1) Make sure that the motion of the landing gear reverses.
2) Make sure that the landing gear goes to its retracted
position.
a) Make sure the components attached to the landing gear
do not interfere with the landing gear as it retracts.
3) Make sure that the landing gear doors close.
4) Make sure that there is no leakage of fluid from the body
landing gear hydraulic system.
5) Make sure that there is no mechanical damage.
6) Make sure that there is no interference between the body
landing gear and the body landing gear doors.
(h) Move the landing gear handle to the "DN" position after the
gear "UP" indication appears on the EICAS upper panel.
1) Make sure that the landing gear is down and locked.
a) Make sure the components attached to the landing gear
do not interfere with the landing gear as it extends.
(i) Move the landing gear control lever to the "UP" position and
then move the landing gear control lever to the "DN" position
uniformly over a time period of approximately 3 seconds when
the landing gear are approximately half way up.
1) Make sure that the landing gear goes to its down and locked
position.
a) Make sure the components attached to the landing gear
do not interfere with the landing gear as it extends.
2) Make sure that there is no leakage of fluid from the body
landing gear hydraulic system.
3) Make sure that there is no mechanical damage.
4) Make sure that there is no interference between the body
landing gear and the body landing gear doors.
(j) Move the landing gear control lever to the "OFF" position after
gear "DOWN" indication appears on the EICAS upper panel.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-33-00
ALL ú ú 01 Page 509 ú Oct 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 865-021
(21)
Remove hydraulic pressure from system No. 1 and 4
(AMM 29-11-00/201).
S 495-022
(22)
Install ground lock pins in all landing gear (AMM 09-11-00/201).
F.
Restore Airplane to Normal
S 585-029
(1)
Lower the airplane back to the ground and remove jacks
(AMM 07-11-01/201).
S 495-030
(2)
Make sure that landing gear ground lockpins are installed in all landing gear (AMM 09-11-00/201).
S 865-031
(3)
Make sure that the landing gear control lever is in the "DN" position.
S 865-032
(4)
Close circuit breakers as follows for applicable systems:
(a)
P7 Overhead Panel
1) 7A03 AURAL WARN L
2) 7A04 AURAL WARN R
S 865-033
(5)
If no longer required, make sure that hydraulic systems No. 1 and 4 are not pressurized (AMM 29-11-00/201).
(6)
If no longer required, remove electrical power (AMM 24-22-00/201).
S 865-034
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-33-00
ALL ú ú 01 Page 510 ú Feb 15/99