(h)
Wind and tighten the cable or chain of the fishpole hoist a sufficient amount to take the weight off of the APU ground support lug.
S 024-023
(2)
Remove the upper fire detector element or assembly. To remove it, do this task: Remove APU Fire Detector Element or Remove APU Fire Detector Assembly (AMM 26-15-02/401).
S 024-007
(3)
Do these steps to remove the vertical support tube (5):
(a)
Remove the two nuts (3), four washers (2), two bolts (1) and two bushings (4) that attach the vertical support tube (5) to the aft shockmount.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
49-13-04
ALL ú ú 01 Page 406 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(b)
Remove the nut (8), washer (7) and bolt (6) that attach the vertical support tube (5) to the airplane structure.
(c)
Remove the vertical support tube (5).
(d)
Make sure you install all necessary protection covers.
TASK 49-13-04-404-010
3. Vertical Support Tube Installation (Fig. 401, Fig. 402)__________________________________
A. References
(1)
AMM 26-15-02/401, APU Fire Detector
B.
Equipment
(1)
PF51-002-1 Hoist - Fishpole, Manual Powered
06714 P. F. Industries Inc.
151 S. Michigan St., Seattle, WA 98108-3225 or
(2)
AP6108 Hoist - Fishpole, Advanced Chain-Driven
Morgan Aero Products
2719 Pacific Avenue, Everett, WA 98201
(3)
2OHME65B00780-1 Sling - APU Rear Mount
C.
Parts ~.............................................................................. | AMM | | AIPC | ................. ............................ | FIG | ITEM | NOMENCLATURE | SUBJECT | FIG | ITEM | ................................................................................ | 402 | 5 | Truss Assembly (Vertical Support | 49-13-51 | 01 | 235 | | | | Tube) | | | | 2.......….......…...................................…...........…......….......1
D.
Access
(1)
Location Zones
221 Control Cabin - Left
222 Control Cabin - Right
310 Fuselage - Station 2360 to Station 2792
(2)
Access Panels
317AL APU Access Door - Left
318AR APU Access Door - Right
E.
Procedure
S 424-008
(1)
Do these steps to install the vertical support tube (5):
(a)
Install the vertical support tube (5) to the airplane structure with the washer (7), bolt (6) and nut (8).
(b)
Install the vertical support tube (5) to the aft shockmount with the two bushings (4), four washers (2), two bolts (1) and two nuts (3).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
49-13-04
ALL ú ú 01 Page 407 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(c) Tighten the three bolts (1), (6) to 50-70 inch-pounds (5.7-7.9 newton-meters).
S 424-021
(2)
Install the upper fire detector element or assembly. To install it, do this task: Install APU Fire Detector Element or Install APU Fire Detector Assembly (AMM 26-15-02/401).
S 084-022
(3)
Remove the fishpole hoist and APU rear mount sling from the APU compartment.
F.
Put the Airplane Back to Its Usual Condition
S 864-017
(1)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a)
P6-2 Main Power Distribution Panel
1) 6K18, APU ALTN CONT
(b)
P83 Aft APU Equipment Control and Circuit Breaker Panel 1) APU PRIME CONT
S 864-018
(2)
Remove the DO-NOT-OPERATE tag from the APU control switch on the P5 overhead panel.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 机载辅助动力 1(72)