(3)
AIPC 27-81-01, Fig. 1
(4)
AIPC 27-81-01, Fig. 5
(5)
AIPC 27-81-01, Fig. 10
(6)
AIPC 27-81-06, Fig. 1
(7)
SSM 27-81-01, SSM 27-81-02, SSM 27-81-03, SSM 27-81-04, SSM 27-81-05, SSM 27-81-06
(8)
WDM 27-51-21, WDM 27-51-22, WDM 27-81-11, WDM 27-81-12, WDM 27-81-21, WDM 27-81-22, WDM 27-81-31, WDM 27-81-32, WDM 27-81-41, WDM 27-81-42, WDM 27-81-81, WDM 27-81-82
C.
Access
(1)
Location Zone
512 Krueger Flap Inboard, LH
513 Krueger Flap Midflap, LH
514 Krueger Flap Outboard, LH
612 Krueger Flap Inboard, RH
613 Krueger Flap Midflap, RH
614 Krueger Flap Outboard, RH
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-81-01
ALL ú ú 03 Page 401 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
D. Prepare for Removal
S 864-002
(1) Do this task: "Supply Electrical Power" (AMM 24-22-00/201).
S 864-003
CAUTION: DO NOT ELECTRICALLY EXTEND OR RETRACT THE FLAPS MORE THAN ONE
_______ TIME IN 5 MINUTES. DAMAGE TO THE MOTOR CAN OCCUR IF THE MOTOR BECOMES TOO HOT.
(2)
Extend the Krueger flaps electrically:
(a)
Push the ALTN FLAPS ARM switch on the center panel to put the flap system in alternate control.
(b)
Turn the ALTN FLAPS EXT/RET switch to the EXT position.
S 864-004
(3)
For the applicable system, open these circuit breakers and attach DO-NOT-CLOSE tags:
(a)
P6 Main Power Distribution Panel
1) 6L21 LE FLAP ELEC CONT GRP B DRIVE 1
2) 6L22 LE FLAP ELEC CONT GRP A DRIVE 2
3) 6L23 LE FLAP ELEC CONT GRP A DRIVE 3
4) 6L24 LE FLAP ELEC CONT GRP A DRIVE 4
5) 6E3 PRIM LE FLAP CONT GRP A AC
6) 6E4 PRIM LE FLAP CONT GRP A DC
7) 6E5 PRIM LE FLAP CONT GRP B AC
8) 6E6 PRIM LE FLAP CONT GRP B DC
(b)
P7 Overhead Circuit Breaker Panel
1) 7C10 FLT CONT ELEC 2L-AC
2) 7C11 FLT CONT ELEC 2L-DC
3) 7C12 FLT CONT ELEC 1L-AC
4) 7C13 FLT CONT ELEC 1L-DC
5) 7C14 FLT CONT ELEC 1R-AC
6) 7C15 FLT CONT ELEC 1R-DC
7) 7C16 FLT CONT ELEC 2R-AC
8) 7C17 FLT CONT ELEC 2R-DC
(c)
P414 Power Distribution Center - Left
1) 414A5 LE FLAP ELEC DRIVE 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-81-01
ALL ú ú 01 Page 402 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
2) 414A2 LE FLAP ELEC DRIVE 4
(d) P415 Power Distribution Center - Right
1) 415M35 LE FLAP ELEC DRIVE 2
2) 415B32 LE FLAP ELEC DRIVE 3
S 494-005
WARNING: YOU MUST CAREFULLY DO THE STEPS IN THE TASK BELOW TO INSTALL
_______ THE LE FLAP SAFETY LOCKS. THE LE FLAPS CAN MOVE QUICKLY IF YOU DO NOT INSTALL THE SAFETY LOCKS CORRECTLY. THIS CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
(4)
Do this task: "Extended Leading Edge Flap Deactivation and Safety Lock Installation" (AMM 27-81-00/201).
S 864-006
(5)
Do this task if electrical power is not necessary "Electrical Power Removal" (AMM 24-22-00/201).
E.
Remove the Krueger Flap
S 034-007
(1)
If it is necessary to remove the folding fairing, hold and remove the folding fairing (Fig. 401):
(a)
Remove the bonding jumpers (3) between the folding fairing and the Krueger flap.
(b)
Remove the bolts (24) that connect each link assembly to the folding fairing.
(c)
Remove the bolts (21) that connect the folding fairing (27) to the Krueger flap (1).
(d)
Remove the folding fairing (27) from the airplane.