* SEE WDM EQUIPMENT LIST
Lift Augmenting - Component Index Figure 101 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-80-00
ALL ú
ú 02 Page 102
ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
FAULT ISOLATION/MAINT MANUAL
PILOTS' CENTER
INSTRUMENT P7 PANEL
PANEL, P2-3 P6 PANEL
SEE A
PILOTS' CONTROL STAND
SEE B
P415 PANEL
E2-2
P414 PANEL E1-2
L,C,R FLAP CONTROL UNITS, M7881,M7880, M7879 (REF)
REVERSE
P2-3 PILOTS' CENTER
THRUST
LEVER (REF) INSTRUMENT PANEL A
A
A
FLAP CONTROL LEVER HANDLE (REF) FLAP
PILOTS' CONTROL STAND B
A-A
Lift Augmenting - Component Location Figure 102 (Sheet 1)
ALTN FLAPS EXT/RET SWITCH, S1709 (REF)
ALTN FLAPS ARM SWITCH, S1710 (REF)
FLAP UP
1
5
10
20
25
30
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-80-00
ALL ú ú 01 Page 103 ú Jun 10/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 FAULT ISOLATION/MAINT MANUAL
(EXAMPLE)OUTBOARDDRIVE ROTARY ACTUATOR (EXAMPLE)
Lift Augmenting - Component Location
Figure 102 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-80-00
ALL ú ú 01 Page 104 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
FAULT ISOLATION/MAINT MANUAL
LEFT, RIGHT LE FLAP
ELECTROPNEUMATIC
DRIVE UNIT NO. 4,
DRIVE M880,M881
SHAFT
LE FLAP
ELECTROPNEUMATIC
DRIVE UNIT (EXAMPLE)
HINGE SEE E SHT 4
OFFSET GEARBOX
ROTARY ACTUATOR
FOLDING FAIRING
FAIRING ACTUATING LINKAGE
KRUEGER FLAP
KRUEGER FLAPS
C
LEFT, RIGHT LE FLAP ELECTROPNEUMATIC DRIVE UNIT NO. 1,2 AND 3 M876,M885,M878,M883, M879,M882
FLAP PANEL LE FLAPROTARY ELECTROPNEUMATICACTUATOR DRIVE UNIT (EXAMPLE)
FOLDING SEE E SHT 4 NOSE
VARIABLE CAMBER FLAPS
D
Lift Augmenting - Component Location (Details from Sht 2)Figure 102 (Sheet 3)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-80-00
ALL ú ú 01 Page 105 ú Oct 10/91
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 7(36)