• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 08:37来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

30  0.97  0.96  0.95  0.94  0.93  0.92  0.91  0.90 
35  0.98  0.97  0.96  0.95  0.94  0.93  0.92  0.91 
40  0.99  0.98  0.97  0.96  0.95  0.94  0.93  0.92 
45  1.00  0.99  0.98  0.97  0.96  0.95  0.94  0.93 
50  1.01  1.00  0.99  0.98  0.97  0.96  0.95  0.94 
55  1.01  1.01  1.00  0.99  0.98  0.97  0.96  0.95 
60  1.02  1.01  1.01  1.00  0.99  0.98  0.97  0.96 
65  1.03  1.02  1.01  1.01  1.00  0.99  0.98  0.97 
70  1.04  1.03  1.02  1.01  1.01  1.00  0.99  0.98 
75  1.05  1.04  1.03  1.02  1.01  1.01  1.00  0.99 
80  1.06  1.05  1.04  1.03  1.02  1.01  1.01  1.00 
85  1.07  1.06  1.05  1.04  1.03  1.02  1.01  1.01 
90  1.08  1.07  1.06  1.05  1.04  1.03  1.02  1.01 
95  1.09  1.08  1.07  1.06  1.05  1.04  1.03  1.02 
100  1.10  1.09  1.08  1.07  1.06  1.05  1.04  1.03 

____________ _______ Tbay is in `F.
Cf = (tbay = 460) * (29.92) Where: 529 Pbar Pbar is in IN. HG.
A 737-300/400/500MAINTENANCE MANUAL
 (3)  
C21001-12 Equipment Cooling System Performance Test Set (alternative)

 (4)  
F80237-13 Equipment Cooling System Performance Test Set (alternative)

 (5)  
Aluminum Foil Marker - BAC27DEX2015


 C. References
 (1)  
AMM 24-22-00/201, Manual Control

 (2)  
AMM 34-28-31/401, Inertial Reference Unit


 D. Procedure
 S 035-022
 (1)  Remove the IRUs from the E3-5 shelf (AMM 34-28-31/401).
TEST PORT  GAGE PRESS IN. H O2  GAGE PRESS CORRECTED IN. H O2  MIN ACCEPTABLE PRESS IN. H O2  OK LOW OR HIGH CORRECTED PRESS STATUS 
1  0.5 
2  0.5 

Test Data Sheet
Figure 504

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. APLS WITH EFIS ú

 21-58-02
 ú ú 02 Page 510 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 S 865-023
 (2)  Supply electrical power (AMM 24-22-00/201).
 S 865-024
 (3)  Make sure these circuit breakers on the P18-3 panel are closed:
 (a) NORMAL SUPPLY FAN POWER
 (b) NORMAL SUPPLY FAN CONTROL
 S 865-025
 (4)  Set the EQUIP COOLING SUPPLY switch on the P5 overhead panel to the
 NORMAL position.
 S 865-026
 (5)  Close the E/E compartment hatch if the ambient temperature is below
 40 degrees Fahrenheit.
 S 285-027
 (6)  Measure the temperature in the E/E Bay between the E-2 and the E-3
 racks with a thermometer.
 S 975-028
 (7)  Make a record of the E/E Bay temperature.
 S 975-029
 (8)  Make a record of the barometric pressure.
 NOTE: The standard barometric pressure for the altitude where the____
 test is done is satisfactory.

 S 215-030
 (9)  
Before you take the pressure measurements, hold the pressure indicator vertically and make sure that it reads "zero".

 S 015-045

 (10)
 Remove the "REMOVE FOR COOLING TEST ONLY" foil markers from the test ports in the cooling supply ducts to the E3-5 shelves.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. APLS WITH EFIS ú

 21-58-02
 ú ú 01 Page 511 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 785-031
 (11)
 Measure and make a record of the pressure at the test ports (Fig. 501 and Fig. 504).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 2(90)