• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 08:37来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 864-026
 (1)  
Supply electrical power (Ref 24-22-00/201).

 S 864-039

 (2)
Energize the circuit breaker panel for the load control, P6-4.

 S 864-027

 (3)  
Remove the DO-NOT-CLOSE tag and close this circuit breaker:


 (a)  P6-4, circuit breaker panel for the load control 1) TEMP IND
 S 714-028
 (4)  
Put the AIR TEMP switch to the PASS CABIN position.

 S 714-041

 (5)  
Make sure the temperature indicator shows approximately the same temperature as the temperature in the cabin.

 S 984-034

 (6)  
Align the slot of the outboard edge of the bullnose with the support beam flange.

 (7)  
Lift the bullnose and install the screws.

 (8)  
Install the PSU assembly (Ref 25-23-61/201).


 S 984-035
 S 434-036
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-62-25
 ALL  ú ú 04 Page 402 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 864-037
 (9)  Remove the electrical power if it is not necessary (Ref 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-62-25
 ALL  ú ú 03 Page 403 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 2(171)