A 737-300/400/500MAINTENANCE MANUAL
F. Troubleshooting Charts
(1) The following chart is for normal operation, ie with selector switch at NORMAL. If problem was encountered with switch at ALTERNATE, substitute alternate fan and alternate fan relay and reverse check valve postions where applicable. For switch continuity in ALTERNATE position check between contacts 4 and 5.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. APLS WITH EFIS ú
21-58-02
ú ú 03 Page 102 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
EFIS COOLING SYSTEM - ADJUSTMENT/TEST
_____________________________________
1. General_______
A. This procedure has two tasks. One task is the EFIS cooling system operational test, and the other task is the EFIS cooling system performance test.
B. The operational test makes sure that all the EFIS cooling system components work. The performance test makes sure that there is sufficient airflow to cool the equipment.
TASK 21-58-02-705-001
2. EFIS Cooling System Operational Test____________________________________
A. References
(1) AMM 24-22-00/201, Manual Control
B. Procedure
S 865-002
(1)
Make sure these circuit breakers are closed:
(a)
P6-1 Load Control Circuit Breaker Panel 1) EFIS SYM GEN R 2) EFIS CONT PNL R 3) EHSI 4) IRS No. 2 AC 5) IRS No. 2 DC
(b)
P18-2 Circuit Breaker Panel
1) INSTRUMENT TRANSFER
2) EFIS SYM GEN L
3) EFIS CONT PNL L
4) IRS No. 1 AC
5) IRS No. 1 DC
(c)
P18-3 Circuit Breaker Panel 1) NORMAL SUPPLY FAN POWER 2) ALTERNATE SUPPLY FAN POWER 3) NORMAL SUPPLY FAN CONT 4) ALTERNATE SUPPLY FAN CONT
(2)
Supply electrical power (AMM 24-22-00/201).
S 865-004
(3)
Set these switches on the P5 panel as follows:
(a)
EQUIP COOLING SUPPLY - NORMAL
(b)
L IRS - NAV
(c)
R IRS - NAV
(4)
Make sure AIR/GND logic is in the GND mode.
S 865-003
S 865-005
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. APLS WITH EFIS ú
21-58-02
ú ú 01 Page 501 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 215-006
(5) Make sure the normal fan operates.
S 865-007
(6) Push in and release either of the MASTER CAUTION lights on the P7