• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 08:37来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1)  AMM 24-22-00/201, Electrical Power
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú

 21-58-00
 ú ú 02 Page 501 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 C. Access
 (1)  Location Zone
 101 Control Cabin - Left
 102 Control Cabin - Right
 205 Electronic Compartment

 D. Procedure
 S 865-001
 (1)  
Supply electrical power (AMM 24-22-00/201).

 S 215-003

 (2)  
Make sure these circuit breakers are closed on the P18 panel:

 (a)  
EQUIP COOLING CONT

 (b)  
BLOWER NORMAL

 (c)  
BLOWER ALTERNATE

 


 S 865-004
 (3)  
If a MASTER CAUTION light and the OVERHEAD light are on, push the MASTER CAUTION light to make the lights go off.

 S 865-005

 (4)
Put the EQUIP COOLING selector switch to NORMAL, at the P5 panel.

 S 715-006

 (5)  
Make sure that the main blower operates.

 S 215-008

 (6)  
Make sure that the flow control valve is open.

 S 215-009

 (7)  
Make sure that the EQUIP COOLING OFF light, on the P5 panel, is off.

 S 215-011

 (8)  
Make sure that the MASTER CAUTION lights and the OVERHEAD light are off.

 (9)  
Put the EQUIP COOLING selector switch to ALTERNATE.

 (10)
 Make sure that the alternate blower operates.

 (11)
 Make sure that the flow control valve stays open.

 S 215-016

 (12)
 Make sure that EQUIP COOLING OFF light, MASTER CAUTION lights, and the OVERHEAD light stay off.


 S 865-012
 S 715-013
 S 215-015
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú

 21-58-00
 ú ú 02 Page 502 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL

Equipment Cooling Rack Location
Figure 501

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú

 21-58-00
 ú ú 02 Page 503 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-018
 (13) Open this circuit breaker on the P18 panel and attach a DO-NOT-CLOSE tag:
 (a) BLOWER ALTERNATE
 S 715-019
 (14)
 Make sure that the alternate blower does not operate.

 S 215-021

 (15)
 Make sure that the EQUIP COOLING OFF light, MASTER CAUTION lights, and the OVERHEAD light come on within 10 minutes.

 S 865-023

 (16)
 Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P18 panel:


 (a) BLOWER ALTERNATE
 S 715-024
 (17)
 Make sure that the alternate blower starts to operate again.

 S 215-026

 (18)
 Make sure that the EQUIP COOLING OFF light goes off within 5 minutes.

 S 865-057

 (19)
 Push the MASTER CAUTION light to make the MASTER CAUTION light and the OVERHEAD light go out.

 S 865-029

 (20)
 Put the EQUIP COOLING selector switch to NORMAL.

 (21)
 Make sure that the main blower operates.

 S 215-031

 (22)
 Make sure that EQUIP COOLING OFF light, MASTER CAUTION lights, and the OVERHEAD light stay off.

 S 865-033

 (23)
 Remove the electrical power if it is not necessary (AMM 24-22-00/201).


 S 715-030
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITHOUT EFIS ú
 