B. Procedure
S 862-002
(1) Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a) P18 panel
1) NORM and ALT COOLING FAN CONT
2) EFIS SYM GEN - L and R
3) EFIS CONT PANEL - L and R
4) EHSI - L and R
5) EADI - L and R
S 032-003
(2)
Remove the clamps which attach the flexible coupling to the check valve and the fan.
S 032-004
(3)
Move the flexible coupling aft to disconnect it from the check valve.
(4)
Remove the coupling which attaches the check valve to the duct.
S 032-005
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EFIS ú
21-58-91
ú ú 01 Page 201 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
ASEE EFIS COOLING CHECK VALVES
E1 RACK (REF)
NOSE WHEEL WELL (REF)
CHECK FLEXIBLE ALTERNATE FAN
VALVE COUPLING (REF)
COUPLING CLAMP CLAMP
DUCT AIR CLEANER
(REF)
DIRECTION
OF AIRFLOW
COUPLING CLAMP OUTBD
CHECK CLAMP VALVE NORMAL
FLEXIBLE FAN (REF)COUPLING
FWD EFIS COOLING CHECK VALVES
A
EFIS Cooling Check Valves Installation
Figure 201
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EFIS ú
21-58-91
ú ú 01 Page 202 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 022-006
(5) Remove the check valve.
TASK 21-58-91-402-007
3. EFIS Cooling Check Valve Installation (Fig. 201)
_____________________________________
A. References
(1) 24-22-00/201, Electrical Power
B. Access
(1) Location Zone
205 Electronic Compartment
C. Install the Check Valve
S 422-008
(1) Attach the check valve to the duct with the coupling:
(a)
Make sure the hinge pin on the check valve is in the vertical position.
(b)
Make sure you align the check valve with the duct correctly.
NOTE: The flapper for the check valve can get caught on the
____ duct if you do not align the check valve correctly.
(c) Tighten the coupling to 25-30 pound-inches.
S 432-009
(2)
Install the flexible coupling to the check valve with the clamps.
S 432-010
(3)
Tighten the clamps to 18-22 pound-inches.
D. Do a Test of the Check Valve
S 862-011
(1) Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a) P18 panel
1) NORM and ALT COOLING FAN CONT
2) EFIS SYM GEN - L and R
3) EFIS CONT PANEL - L and R
4) EHSI - L and R
5) EADI - L and R
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EFIS ú 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 2(117)