S 024-007
(5)
Remove the temperature controller.
TASK 21-52-12-404-002
3. Ram Air Temperature Controller Installation (Fig 401)___________________________________________
A. Access
(1) Location Zones
211 Left Ram Air Duct
213 Right Ram Air Duct
B. Procedure
S 434-008
(1) Put the temperature controller in position for installation.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-52-12
ALL ú ú 02 Page 401 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
RAM AIR DUCT
ACCESS DOOR
RAM AIR
INLET RAM AIR
EXIT
EQUIPMENT BAY DOORS
FWD
TEMPERATURE
CONTROLLER
SEE A
SCREW
WASHER
(4 LOCATIONS)
TEMPERATURE
CONTROLLER
ELECTRICAL
CONNECTOR
TEMPERATURE CONTROLLER
A
Ram Air Actuator Temperature Controller Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-52-12
ALL ú ú 02 Page 402 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
E60954
A
737-300/400/500MAINTENANCE MANUAL
RAM AIR DUCT ACCESS DOOR
A-A
Ram Air Actuator Temperature Controller - Adjustment Figure 402
F64783
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH RAM AIR EXHAUST LOUVERS ú
21-52-12
(PRE-SB 21-1123) ú ú 03 Page 403 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
S 434-010
(2)
Install the screws and washers in the temperature controller.
S 434-009
(3)
Connect the electrical connector.
C. Ram Air Temperature Controller Installation Test
S 864-011
(1) Close these circuit breakers and remove the DO-NOT-CLOSE tags:
(a) On the main power distribution panel, P6:
1) 6E1 AIR COND RAM MOD RIGHT
2) 6E1 AIR COND RAM MOD LEFT
S 714-013
(2) Do the steps that follow to test the ram air temperature controller:
(a)
Make sure the applicable air-conditioning pack is off for more than 30 minutes.
(b)
Extend the flaps (AMM 27-51-00/001).
(c)
Open the ECS bay doors to get access to the flow control and shutoff valve.
(d)
Disconnect the D486 (D490) connector from the left (right) flow control and shutoff valve.
(e)
Push and hold the the ground sensing test switch to put the airplane in the air mode.
(f)
Retract the flaps (AMM 27-51-00/001). 1) Make sure the RAM DOOR FULL OPEN light is off. 2) Disconnect the D966 (D968) from the left (right) ram air
door actuator.
3) AIRPLANES WITH RAM AIR EXHAUST LOUVERS (PRE-SB 21-1123); Make sure the dimensions between the exhaust louvers for the ram air exhaust is 0.65 to 1.00 inches (Fig. 402).
4) Reconnect the D966 (D968) connector to the left (right) ram air door actuator.
(g)
Disconnect the D1288 (D1290) connector from the left (right) ram air temperature sensor. 1) Install a jumper between pins 1 and 2 on the connector. 2) Make sure the RAM AIR FULL OPEN light on the P5 panel comes
on. 3) Remove the jumper from the D1288 (D1290) connector.
(h)
Reconnect the D1288 (D1290) connector to the left (right) ram air temperature sensor. 1) AIRPLANES WITH RAM AIR EXHAUST LOUVERS
(PRE-SB 21-1123);
Make sure the ram air inlet door and exhaust louvers move
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 2(54)