A
737-300/400/500MAINTENANCE MANUAL
Access
(1) Location Zones 212 Left Air Conditioning Equipment Bay 214 Right Air Conditioning Equipment Bay
Procedure
S 644-011
(1)
Put a small quantity of the antiseize compound on the threads of the 35° temperature sensor.
S 424-012
(2)
Install the 35°F temperature sensor in the water separator.
(a) Install the lockwire.
S 984-013
(3)
Put the water separator in the support bracket with the flow arrow pointed forward.
S 424-014
(4)
Install but do not tighten the support clamp.
S 984-015
(5)
Turn the water separator to align the electrical connector, the extractor boss, and the drain boss.
S 424-016
(6)
Install but do not tighten the duct clamps.
S 434-017
(7)
Tighten the support bracket clamp of the water separator.
S 434-018
(8)
Tighten the duct clamps.
S 434-019
(9)
Install the overboard drain seal and the clamp to the drain boss.Do a Test of the Water Separator.
(1)
Supply electrical power (Ref 24-22-00/201).
(2)
Pressurize the pneumatic system (Ref 36-05-00/201).
S 864-020
S 864-021
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-51-31
ALL ú ú 02 Page 402 ú Jul 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 794-023
(3) Operate the air conditioning system with the mixture valve at full cold and examine the separator for air leakage at the clamps.
NOTE: A small leak is OK.
You must repair a large leak
S 794-024
(4) Make sure there is a vacuum at the water injector line.
(a) Put your hand against the line and feel for a vacuum.
S 714-025
(5)
Make sure that the 35°F control valve position indicator is at full open.
S 434-026
(6)
Install ther electrical connector for the temperature sensor.
S 714-028
(7)
Make sure these conditions occur:
(a)
The 35°F valve first goes to the closed position.
(b)
The valve moves to control the flow.
S 864-029
(8)
Remove the pneumatic power if it is not necessary
(Ref. 36-05-00/201).
S 864-030
(9)
Put the pack switches to OFF.
S 434-031
(10)
Connect the injector line for the water spray to the extractor boss with a new O-ring.
F. Put the Airplane Back to its Usual Condition
S 434-032
(1)
Close the equipment bay door for the air conditioning.
S 434-033
(2)
Remove the electrical power if it is not necessary
(Ref. 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-51-31
ALL ú ú 02 Page 403 ú Jul 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500
MAINTENANCE MANUAL
SEE B
SEEA FWD
A
SUPPORT
BRACKET
35`F TEMPERATURE SENSOR ELECTRICAL CONNECTOR
DUCT CLAMP
DUCT
CLAMP
CLAMP
OVERBOARD DRAIN SEAL
WATER SPRAY
CONNECTOR
EXTRACTOR BOSS SEE C SUPPORT
BRACKET TO WATER
CLAMP SPRAY INJECTOR
FWD
B
BOSS
CONNECTOR
0-RING
C
Water Separator Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 2(27)