Open these circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  P18 panel
 1) NORM and ALT COOLING FAN CONT
 2) EFIS SYM GEN - L and R
 3) EFIS CONT PANEL - L and R
 4) EHSI - L and R
 5) EADI - L and R


 (2)  
Remove the electrical connector from the fan.

 (3)  
Remove the clamps which attach the flexible couplings to the fan.

 (4)
Remove the clamp which attaches the fan to the fan support.


 S 034-003
 S 034-004
 S 034-005
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EFIS ú

 21-58-81
 ú ú 01 Page 401 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
AIR CLEANER (REF)

DIRECTION OF AIRFLOW
NORMAL FAN SUPPORT
EFIS COOLING FANS

A
EFIS Cooling Fans Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EFIS ú

 21-58-81
 ú ú 01 Page 402 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 S 024-006
 (5)  
Remove the fan.

 S 214-020

 (6)  
Examine the check valve that is downstream of the fan:

 (a)  
Make sure that the flapper for the check valve does not catch on the 2-inch duct that is downstream.

 (b)  
Replace the check valve if the flapper catches on the 2-inch duct (Ref 21-58-91/201).

 


 TASK 21-58-81-404-007
 3. EFIS Cooling Fan Installation (Fig. 401)
_____________________________
 A. References
 (1)  24-22-00/201, Electrical Power
 B. Access
 (1)  Location Zone
 205 Electronic Compartment

 C. Install the Fan
 S 424-008
 (1)
Attach the fan to the flexible couplings on the fan support.

 S 214-009

 (2)  
Make sure the electrical connector for the fan is on the top side of the fan.

 S 434-010

 (3)
Install the clamp which attaches the fan to the fan support.

 S 434-011

 (4)  
Tighten the clamp.

 S 434-012

 (5)  
Install the clamps which attach the flexible couplings to the fan.

 S 434-013

 (6)  
Tighten the clamps to 18-22 pound-inches.

 S 434-014

 (7)  
Install the electrical connector to the fan.


 D. Do a Test of the Fan
 S 864-016
 (1) Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 (a)  P18 panel
 1) NORM and ALT COOLING FAN CONT

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EFIS ú

 21-58-81
 ú ú 01 Page 403 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 2) 3) 4) 5)  EFIS SYM GEN - L and REFIS CONT PANEL - L and REHSI - L and READI - L and R
 (2)  S 864-015Supply electrical power (Ref 24-22-00/201).
 (3)  S 864-017Put the EQUIP COOLING SUPPLY switch to NORMAL or ALTERNATE on the P5 overhead panel for the applicable fan.
 (4)  S 714-018Make sure that the applicable fan operates and that there is no air leakage from the flex hose connections.
 (5)  S 864-019Remove the electrical power, if it is not necessary (Ref 24-22-00/201).