S 034-029
CAUTION:_______DO NOT LOWER THE PANEL MORE THAN NECESSARY. IF YOU LOWER THE PANEL MORE THAN NECESSARY, YOU CAN CAUSE DAMAGE TO THE FLEXIBLE DUCT THAT CONNECTS TO THE SENSOR FAN.
(3)
Remove the fasteners that attach the ceiling panel to the structure.
S 014-026
(4)
Lower the panel sufficiently to get access to the sensor bracket fasteners.
S 034-004
(5)
Remove the sensor bracket fasteners and remove the bracket with the sensor attached from the sensor box.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-61-61
ALL ú ú 03 Page 401 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
TEMPERATURE SENSOR SEE A
CONTROL CABIN
FASTENER (2 LOCATIONS)
SENSOR BRACKET
FLANGE
TEMPERATURE FASTENER
SENSOR (2 LOCATIONS)
ELECTRICAL
CONNECTOR FILTER
CEILING
PANEL
AIR INLET
GRILLE
WASHER
(4 LOCATIONS)
SCREW
(4 LOCATIONS)
TEMPERATURE SENSOR
A
Control Cabin Temperature Sensor Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-61-61
ALL ú ú 01 Page 402 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 034-005
(6)
Remove the electrical connector of the temperature sensor.
S 024-006
(7)
Remove the sensor flange fasteners and remove the sensor from the bracket.
TASK 21-61-61-404-007
3. Install the Temperature Sensor for the Control Cabin (Fig. 401)____________________________________________________
A. References
(1)
24-22-00/201, Electrical Power
(2)
36-05-00/201, Pneumatic System
B. Access
(1) Location Zone
101 Control Cabin, Left
C. Procedure
S 424-008
(1)
Install the temperature sensor on the sensor bracket.
S 434-009
(2)
Install the electrical connector to the temperature sensor.
S 434-010
(3)
Put the sensor bracket on the sensor box and install the fasteners.
S 414-011
(4)
Install the ceiling panel.
S 434-012
(5)
Install the grille and the filter.
D. Do a Test of the Temperature Sensor
S 864-013
(1) Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a) P6-4 Panel
1) 6A4, TEMP CONTROL, AUTOMATIC, L
S 864-024
(2)
Make sure all the other circuit breakers for the air conditioning are closed.
(3)
Supply electrical power (Ref 24-22-00/201).
(4)
Supply pressure to the pneumatic system (Ref 36-05-00/201).
S 864-014
S 864-015
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-61-61
ALL ú ú 02 Page 403 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 864-016
(5) Remove the DO-NOT-OPERATE identifiers from the L and R PACK switches
and put the L PACK switch to the AUTO or the HIGH position.
S 864-017
(6) Put the temperature selector for the control cabin to the AUTO COOL
position and then to the OFF position to move the mixture valve to
the COLD position.
NOTE:____ If the cabin temperature is below approximately
65°F (18.3°C), you must supply warm air to the sensor.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 2(161)