D. Prepare for the Pressure Check
S 216-005
(1)
Make sure the relief valve is closed.
S 446-006
(2)
If the relief valve is open, do this task: "Close the Relief Valve Manually".
S 486-007
(3)
Install the F80166 test fixture on the relief valve.
(a) Remove four of the eight mounting screws which attach the relief valve to the access panel. 1) Remove these screws and make sure the remaining screws have
equal angles of 90 degrees between them.
NOTE: The remaining screws are the corners of a square.
____
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH THE PRESSURE RELIEF VALVE ú
28-13-41
ú ú 01.1 Page 602 ú Jul 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
MANUAL MANUAL
SURGE TANK ACCESS SURGE TANK ACCESS PANEL (NO. 13) PANEL (NO. 13)
PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE (KNOB TYPE) (T-HANDLE TYPE) (VALVE CLOSED POSITION) (VALVE CLOSED POSITION)
Surge Tank Flame Arrester Pressure Relief Valve Manual Reset
Figure 601
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH THE PRESSURE RELIEF VALVE ú
28-13-41
ú ú 01 Page 603 ú Mar 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
PRESSURE RELIEF VALVE
TEST FIXTURE F80166
Surge Tank Flame Arrester Pressure Relief Valve Actuation Pressure Check
Figure 602 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH THE PRESSURE RELIEF VALVE ú
28-13-41
ú ú 01.1 Page 604 ú Jul 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
GLOBE SHUTOFF
SHOP AIR INPUT
LEAK TRACING DEVICE F71329
Surge Tank Flame Arrester Pressure Relief Valve Actuation Pressure Check
Figure 602 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH THE PRESSURE RELIEF VALVE ú
28-13-41
ú ú 01.1 Page 605 ú Jul 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
M91844
A
737-300/400/500MAINTENANCE MANUAL
(b) Put the test fixture against the relief valve.
NOTE:____ The MS29513-154 O-ring seal is part of the test fixture
assembly.
1) Make sure the MS29513-154 O-ring seal is installed in the
flange groove of the test fixture.
2) Make sure the O-ring has a good seal in all positions.
(c) Attach the test fixture to the relief valve.
NOTE:____ The MS16998-31 screws are part of the test fixture
assembly.
1) Put four MS16998-31 screws in the positions of the four
usual mounting screws that you removed before this step.
ú
ú S 486-008
ú (4) Attach the hose of the pressure gage or manometer to the adapter
fitting at the bottom of the F80166-1 test fixture.
(a) Make sure there are no air leaks in the hose or the fittings.
S 486-009
(5) Connect the F80166-1 hose assembly to the F71329 leak tracer.
NOTE:____ You use the F71329 leak tracer only to adjust and control
the pressure on the relief valve.
ú (a) To put positive pressure on the pressure relief valve, do these
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 燃油 FUEL 2(15)