A
737-300/400/500MAINTENANCE MANUAL
 S 424-031 CAUTION: DO NOT LOOSEN OR PUT THE O-RING OUT OF ITS CORRECT SHAPE
_______
 WHEN YOU INSTALL THE VALVE BODY ASSEMBLY. MAKE A GOOD SEAL. THE O-RING WILL NOT
 (4)  Install the valve body assembly. (a) One person out of the tank and one person in the tank are necessary for this task. (b) The person in the tank must put the valve body assembly in the correct position between the fittings on the APU line. (c) The person out of the tank must hold the valve body assembly up until it is installed. (d) Install the adapter and the mounting screws for the valve body assembly.
 (5)  S 434-033Attach the APU fuel line to the valve body assembly.
 (6)  S 434-034Do this task, "APU Shutoff Valve Actuator Assembly Installation".
 (7)  S 414-035Install the access panel (7202) for the No. 1 fuel tank (AMM 28-11-11/401).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-31
 ALL  ú ú 01 Page 406 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 APU FUEL SHUTOFF VALVE - ADJUSTMENT/TEST
________________________________________
 1.  General_______
 A.  This procedure has one task, an operational test of the APU shutoff valve.
 TASK 28-22-31-715-001
 2.  APU Shutoff Valve Operational Test (Fig 501)__________________________________
 A.  Access
 (1)  Location Zones
 101 Control Cabin Left
 102 Control Cabin Right
 310 Left Wing Wheel Well

 B.  Procedure
 S 865-015
 (1)  Make sure this circuit breaker is closed:
 (a)  P6 Main Power Distribution Panel
 1) APU CONT

 S 865-016
 (2)  
Set the battery switch to the ON position.

 S 715-017

 (3)  
Set the APU master switch to the ON position.


 (a)  Make sure the valve override handle moves to the OPEN position.
 S 715-028
 (4)  
On the engine and APU fire control module on the control stand aft electronic control panel, P8, pull the APU fire handle.

 (5)
Make sure the valve override handle moves to the closed position.

 S 715-022

 (6)  
On the engine and APU fire control module on the control stand aft electronic control panel, P8, push the APU fire handle in to the stowed position.


 S 715-021
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-31
 ALL  ú ú 02 Page 501 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
ENGINE NO. 1
WING REAR SPAR SEE B
APU FUEL VALVE SEE A
O-RING UNION WITH  HANDLE OVERRIDE MANUAL  APU FUEL VALVE 
APU FUEL VALVE 

WING REAR SPAR 
MOUNTING SCREW BODY ASSEMBLY 
MOUNTING SCREW ACTUATOR 
ASSEMBLY VALVE BODY  O-RING  PLUG ELECTRICAL 
ACTUATOR ASSEMBLY MOUNTING ADAPTER 
FWD  INBD  BONDING JUMPER 

Figure 501 APU Fuel Shutoff Valve 

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-31
 ALL  ú ú 01 Page 502 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (7)  S 715-023Make sure the valve override handle moves to the open position.
 (8)  S 715-024On the APU remote fire control panel, P28, on the aft bulkhead of the right main wheel well, pull the APU remote fire handle.
 (9)  S 715-025Make sure the valve override handle moves to the closed position.
 S 715-026

 (10)
 On the APU remote fire control panel, P28, on the aft bulkhead of the right main wheel well, push the APU remote fire handle to the stowed position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 燃油 FUEL 2(129)