曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
24-22-00-860-811 Supply Electrical Power (P/B 201)
27-51-00-980-801 Trailing Edge Flap System Manual Operation (P/B 201)
27-58-01-000-801 Flap Position Transmitter Removal (P/B 401)
27-58-01-400-801 Flap Position Transmitter Installation (P/B 401)
29-11-00-860-801 Hydraulic System A or B Pressurization (P/B 201)
29-11-00-860-805 Hydraulic System A or B Power Removal (P/B 201)
C. Location Zones
Zone Area
117 Electrical and Electronics Compartment - Left
118 Electrical and Electronics Compartment - Right
212 Flight Compartment - Right
544 Left Wing - Fairing Flap Support No. 1
644 Right Wing - Fairing Flap Support No. 8
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-58-01
Page 501
Oct 10/2003
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
D. Access Panels
Number Name/Location
117A Electronic Equipment Access Door
E. Prepare for the Adjustment
SUBTASK 27-58-01-860-010
(1) Do this task: Supply Electrical Power, TASK 24-22-00-860-811.
SUBTASK 27-58-01-860-011
(2) Make sure the system B hydraulic power is off. If it is on, do this task: Hydraulic System A or B
Power Removal, TASK 29-11-00-860-805.
SUBTASK 27-58-01-420-003
(3) If the flap position transmitter is not installed, then install it. To install the flap position
transmitter, do this task: Flap Position Transmitter Installation, TASK 27-58-01-400-801.
F. Flap Position Transmitter Adjustment
SUBTASK 27-58-01-010-001
(1) To get access to the FSEU in the main equipment center, do this step.
Open this access panel:
Number Name/Location
117A Electronic Equipment Access Door
SUBTASK 27-58-01-730-001
(2) Use the FSEU to read the sensor inputs from the applicable flap position transmitter to the FSEU:
(a) Push the ON/OFF button on the front panel of the FSEU to turn on the display.
NOTE: The display will show EXISTING FAULTS?
(b) Push the down arrow until OTHER FUNCTNS? shows on the display.
(c) Push the YES button to select OTHER FUNCTNS? on the FSEU.
(d) Push the down arrow until I/O MONITOR? shows on the display.
(e) Push the YES button to select I/O MONITOR? from the menu.
(f) Push the down arrow until SYNCRO INPUTS? shows on the display.
(g) Push the YES button to select SYNCHRO INPUTS? from the menu.
(h) Push the down arrow until the applicable L FL POS, or R FL POS shows on the display.
NOTE: The FSEU will continue to show the applicable left or right position transmitter
output.
NOTE: If you do not push any buttons for five minutes, the display will turn off. To keep
the display active, push the down arrow and then the up arrow buttons
occasionally.
SUBTASK 27-58-01-860-012
WARNING: MOVE ALL PERSONS AND EQUIPMENT AWAY FROM THE TRAILING EDGE FLAPS,
AND THE LEADING EDGE FLAPS AND SLATS. THESE SURFACES WILL MOVE AND
CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT.
(3) Move the ALTERNATE FLAPS ARM switch on the P5 panel to arm the alternate control system.
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-58-01
Page 502
Oct 10/2003
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
SUBTASK 27-58-01-860-013
CAUTION: WAIT A MINIMUM OF 15 SECONDS AFTER THE FLAPS STOP BEFORE YOU USE THE
ALTERNATE SYSTEM TO MOVE THE FLAPS AGAIN. YOU CAN CAUSE DAMAGE TO
THE FLAP ALTERNATE MOTOR.
(4) Move the ALTERNATE FLAPS control switch to UP or DOWN to move the trailing edge flaps.
Move the trailing edge flaps until the L FL POS or R FL POS indication on the FSEU is
approximately 180 degrees.
NOTE: This is an initial position for the flaps. The position of the flaps will be set more
accurately in subsequent steps.
SUBTASK 27-58-01-860-014
(5) Move the ALTERNATE FLAPS control switch to DOWN to make sure the indication on the FSEU
increases.
(a) If the indication decreases, the flap position transmitter is installed on the wrong wing.
SUBTASK 27-58-01-860-015
(6) Move the trailing edge flaps until the L FL POS or R FL POS indication is at 180.0 ±0.4 degrees.
NOTE: You can use the manual drive on the flap power drive unit, or the alternate flaps control
to move the flaps.
(a) To use the manual drive to move the flaps, do this task: Trailing Edge Flap System
Manual Operation, TASK 27-51-00-980-801.
(b) To use the alternate flaps control, move the ALTERNATE FLAPS control switch until the
indication is in the limit.
SUBTASK 27-58-01-860-016
(7) Open these circuit breakers and install safety tags:
F/O Electrical System Panel, P6-2
Row Col Number Name
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
737-600-700-800-900 飞机维护手册5 AIRCRAFT MAINTENANCE MANUA(122)