32-31-00
 ALL  ú ú 02 Page 4 ú Mar 15/94 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
737-300/400/500MAINTENANCE MANUAL  
GEAR DOWN CONTROL CABLE LGVB  ROLLER  COMPRESSION SPRING  CONTROL LEVER DRUM INNER SHAFT OUTER SHAFT  LANDING GEAR CONTROL LEVER  
GUIDE  
LOCK STOP  
CONTROL GEAR UP CABLE LGVA  OVERRIDE TRIGGER  
CONTROL LEVER LOCK  LOCK SOLENOID  
LEVER IN DOWN POSITION 
LEVER INNER END OUT OF DETENT
OVERRIDE TRIGGER PULLED TO ALLOW INNER 
END OF LEVER TO CLEAR LOCK STOP
Landing Gear Control Lever Schematic 
Figure 3
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 32-31-00
 ALL  ú ú 01 Page 5 ú Oct 20/83 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 737-300/400/500MAINTENANCE MANUAL
NOTES:_____ 1.  SWITCH CONTACTS ARE CLOSED WHEN CONDITION IS AS INDICATED BY SWITCH TITLE 
2.  SWITCHES ARE REPRESENTATIVE ONLY AND MAY BE CONVENTIONAL SWITCHES OR PROXIMITY SWITCHES 
Landing Gear Control Lever Lock Control Logic Flow Diagram 
Figure 4
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 32-31-00
 ALL  ú ú 01 Page 6 ú Oct 20/83 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 737-300/400/500MAINTENANCE MANUAL
 7.  Flow Limiter Bypass Valve
_________________________
 A.  A flow limiter and a bypass valve are installed in the landing gear hydraulic supply downstream from the transfer valve. The bypass valve is normally open and permits fluid to bypass the flow limiter. Under certain air mode conditions with high hydraulic fluid flow requirements, the bypass valve closes to give priority to the wing leading edge autoslat extension. This limits flow to the landing gear. When the flow requirments decrease, the bypass valve opens and the landing gear system returns to normal.
 8.  Operation
_________
 A.  When the control lever is pulled, the inner end is raised from a detent to free the lever for movement into another position. Moving the lever up or down rotates a cable drum to operate cables running from a quadrant above the left wheel well ceiling. As the quadrant rotates, it operates the landing gear selector valve on the underside of the ceiling through a shaft, lever, and an adjustable link. Releasing the landing gear lever when the desired position has been selected allows the lever end to drop into a detent and so hold the lever in position. In DN position, the lever end operates a control lever position switch for the indicating and warning system.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 起落架 LANDING GEAR 2(47)