UP
DOWN
PORT
PORT
IN TRANSIT CONDITION
Transfer Cylinder Schematic
Figure 6
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-33-00
ALL ú ú 04 Page 8 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
10. Operation_________
A. Retraction
(1) When the landing gear control lever is moved to UP position for gear retraction, hydraulic pressure is directed through the selector valve and the nose gear modular package to the gear and the lock actuators. Flow to the gear actuator is controlled by a flow limiting valve. Flow leaving the lock actuator is controlled by a restrictor (Fig. 8). The lock actuator starts retracting to apply a downward force to an extension on the lock link. The downward force pulls the lock link over center and starts both the lock strut and drag brace folding. As gear retraction proceeds, the lock link assembly swings through 90 degrees from horizontal to vertical position. In so doing, the lock link extension passes across an overcenter position with respect to the lock actuator. From this point, the lock actuator retracting force is opposed to lock link movement until the gear is almost retracted. During the opposition period, the larger main gear actuator overpowers the lock actuator. The unlock force provided by the lock actuator when the gear is down, becomes the locking force when gear is up. The changeover is caused by the lock link extension moving from the aft to the forward side of the lock link pivot (Fig. 9).
UPPER DRAG BRACE
LUG
BELL
CRANK
PUSHROD
DOOR
FITTING
LOWER DRAG
BRACE
RIGHT
DOOR
LEFT DOOR
Nose Gear Door Linkage Figure 7
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-33-00
ALL ú ú 04 Page 9 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(INTERNAL TO ACTUATOR) TWO WAY RESTRICTOR
C1 C2 C1 C2 C1 C2 NOSE GEAR ACTUATOR (PORT MOUNTED) TWO WAY RESTRICTOR
CYLINDER TRANSFER DOWN UP ACTUATOR NOSE GEAR LOCK
R DOWN P R SELECTOR VALVE OFF P R UP P LIMITER FLOW VALVE PRIORITY
NOSE GEAR MODULAR PACKAGE
3550
3550
STEERING TO NOSE WHEEL NOSE GEAR FUSE RESTRICTOR TWO WAY
TO MAIN GEAR DOWN LINE UP LINE TO MAIN GEAR
RETURN LEGEND: DAMPER TO MAIN GEAR R C1 P C SELECTOR VALVE
PRESSURE
"B" SYSTEM VALVE TRANSFER SYSTEM LANDING GEAR LIMITER FLOW VALVE BYPASS
RETURN
SYSTEM "A" PRESSURE
Nose Gear Extension and Retraction Hydraulic System Schmatic
Figure 8
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-33-00
ALL ú ú 04 Page 10 ú Nov 15/97
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 起落架 LANDING GEAR 2(107)