AMM 24-22-00/201, Electrical Power Control

 (3)  
AMM 27-31-00/201, Elevator and Tab Control System

 (4)  
AMM 29-15-00/201, Hydraulic Systems


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 22-11-30
 ALL  ú ú 01 Page 509 ú Mar 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 B.
C.
D.

A
737-300/400/500MAINTENANCE MANUAL
Access
 (1)  Location Zone
 102 Control CabinPrepare for Test
 S 865-065
 (1)  Supply electrical power (AMM 24-22-00/201).
 S 865-076
 WARNING:_______ MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF ALL CONTROL
 SURFACES BEFORE YOU SUPPLY HYDRAULIC POWER.  AILERONS, RUDDERS,
 ELEVATORS, FLAPS, SPOILERS, LANDING GEAR, AND THRUST REVERSERS
 CAN MOVE QUICKLY WHEN YOU SUPPLY HYDRAULIC POWER.  THIS CAN

 CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (2)
Supply hydraulic pressure (AMM 27-31-00/201).

 S 865-069

 (3)  
Make sure the autopilot, attitude, compass, and air data systems on


 the P6 and P18 circuit breaker panels are closed.Actuator/Sensor Test
 S 865-070
 (1)  
Put the autopilot A (or B as applicable) engage switch to CWS.

 S 755-080

 (2)  
Make sure CWS roll and CWS pitch lights come on.

 S 865-071

 (3)  
Push the control column and make sure that the pressure necessary to move the column increases.

 S 755-081

 (4)  
Make sure the elevator moves down.

 S 865-072

 (5)  
Pull the control column and make sure the elevator moves up.

 S 865-073

 (6)  
Put the control column to the center and disengage the autopilot.

 S 865-074

 (7)  
Remove electrical power if it is not necessary.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 22-11-30
 ALL  ú ú 02 Page 510 ú Mar 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-075
 (8) Remove hydraulic power if it is not necessary.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 22-11-30
 ALL  ú ú 01 Page 511 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 STABILIZER POSITION SENSOR - REMOVAL/INSTALLATION
_________________________________________________
 1.  General (Fig. 401)_______
 A.  This procedure contains two tasks. The first is for the removal of the stabilizer position sensor. The second is the installation of the stabilizer position sensor.
 B.  The stabilizer position sensors are connected to the stabilizer position crank arms and are installed on the aft bulkhead station 1156 (Ref 27-31-00/201, Elevator and Tab Control System). The stabilizer position sensors are found on opposite sides of the elevator feel mechanism.
 TASK 22-11-31-024-001
 2.  Stabilizer Position Sensor Removal__________________________________
 A.  References
 (1)  
12-31-01/201, General Zone Diagram

 (2)  
27-31-00/201, Elevator and Tab Control System


 B.  Access
 (1)  
Location Zone
 705 Tail Cone Access Door


 (2)  
Access Panel
 3802 Tail Cone Access Door

 

 C.  Prepare for Removal
 S 014-002
 (1)  
Remove access panel 3802 on the tail cone (Ref 12-31-01/201, Access Doors and Panels).

 S 864-003

 (2)
Open these circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  
P6 Circuit Breaker Panel 1) AUTO FLT CONT SYS B MACH TRIM AC 2) AUTO FLT CONT SYS B SNSR EXC AC
 