C. Disconnect electrical cable from battery warning logic module.
D. Remove three self-locking hexnuts.
E. Pull off battery warning logic module.
4. Install INS Battery Warning Logic Module________________________________________(See figure 401.)
A. Secure battery warning logic module to INS mounting rack with three machine screws and self-locking hexnuts.
B. Connect electrical cable to unit.
C. Install No. 2 and 3 INS navigation units.
NOTE: Do not perform test called for in last step of INS navigation
____
unit installation procedure.
D. After installing, test by performing INS battery warning logic module test. Refer to 34-41-16.
EFFECTIVITY
ALL 01 Page 401 Oct 10/7334-41-16
E2-6 SHELF
SEE A
SEE BINU MOUNTING RACK
FWD FWD
B INS BATTERY WARNING LOGIC MODULE A
INS Cooling Fan - Removal/Installation Figure 401
754965
EFFECTIVITY
701 Page 402
ALL 34-41-16
Oct 10/73
INS BATTERY WARNING LOGIC MODULE - ADJUSTMENT/TEST
__________________________________________________
1. INS Battery Warning Logic Module Test
_____________________________________
A. General
(1) The INS battery warning logic module alerts the ground crew if power is removed from the airplane without first turning off all INS systems. This test verifies that the ground crew call horn (in the nose wheel well) will be activated 30 (| 10) seconds after any INS system switches to battery power due to loss of its primary 115-volt ac power source.
NOTE: On airplanes AF 112-115, 151, plus airplanes incorporating
____ SB 32-2141, the ground crew call horn will sound if the INS circuit breakers are opened but will not sound if power is removed from the airplane.
On AF 116-150, 152-199; LH 011-030, 051-070, 082-099; AZ 221-299; IB 406-499; MD 501-599; GN 601-699; AT 701-750; VM 751-799; plus airplanes incorporating SB 34-2080, the ground safety relay is bypassed and the ground crew call horn will sound if the INS is left operating when power is removed from the airplane.
B. Referenced Procedures
(1)
21-58-00, Equipment Cooling - Adjustment/Test (Operational Test)
(2)
24-22-00, Manual Control - Maintenance Practices (Apply Power)
C. Prepare for Test
(1)
Set mode selector switch on each INS mode selector unit in pilots' overhead panel P5 to OFF position.
(2)
Provide electrical power. Refer to 24-22-00.
(3)
Provide cooling air to INS equipment. Refer to 21-58-00.
CAUTION: ENSURE THAT COOLING AIR IS AVAILABLE TO NAVIGATION UNITS
_______ BEFORE OPERATING INS. FAILURE TO PROVIDE ADEQUATE AIR SUPPLY WILL RESULT IN FAILURE OF NAVIGATION UNITS.
(4) Close all PWR-INS 1, PWR-INS 2 and PWR-INS 3 circuit breakers on electronic circuit breaker panel P7 (or P126).
D. Test INS Battery Warning Logic Module
(1)
Set MSU No. 1, 2 and 3 mode selector switches to STBY.
(2)
Open 10 amp PWR-INS 1 circuit breaker and verify that:
(a)
No. 1 INS CDU BAT light illuminates.
(b)
Warning alarm sounds 30 (| 10) seconds after the circuit breaker is opened.
(3)
Close 10 amp PWR-INS 1 circuit breaker and verify that the warning alarm ceases.
(4)
Open 10 amp PWR-INS 2 circuit breaker and verify that:
(a)
No. 2 INS CDU BAT light illuminates.
(b)
Warning alarm sounds 30 (| 10) seconds after the circuit breaker is opened.
EFFECTIVITY
ALL 21 Page 501 Aug 25/8134-41-16
(5)
Close 10 amp PWR-INS 2 circuit breaker and verify that the warning alarm ceases.
(6)
Open 10 amp PWR-INS 3 circuit breaker and verify that:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn