(d)
Let the sealant dry until it is hard.
S 864-109
(4) Remove electrical power if it is not necessary (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-45-02
ALL ú ú 02 Page 405 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
TCAS COMPUTER - SOFTWARE INSTALLATION
_____________________________________
1. General_______
A. The task in this procedure is the TCAS Computer software installation. The task is provided because the airborne data loader (ADL) cannot be used to load the TCAS computer and must be disconnected. The ADL can be found in the P11 panel.
TASK 34-45-10-802-001
2. TCAS Computer Software Installation___________________________________
A. Special Tools and Equipment
(1) 30100 - Portable Data Loader (PDL) Demo Systems, Moorpark CA
NOTE:____The PDL is not a Boeing supplied item. This coverage is included for information only. See the data loader instructions, which are supplied by the vender, to do the navigation data base installation.
B. References
(1)
AMM 24-22-00/201, Manual Control
(2)
AMM 06-09-01/201, Access Door and Panels
C. Access
(1) Location Zones
118 Electrical/Electronics Compartment
222 Control Cabin, RH
D. Prepare for the Software Installation
S 862-019
CAUTION: MAKE SURE THE CIRCUIT BREAKER FOR THE DATABASE LOADER IS OPEN
_______ BEFORE YOU REMOVE THE AIRBORNE DATA LOADER (ADL). DAMAGE TO THE ADL CAN OCCUR.
(1) Make sure this circuit breaker is open:
(a) P6 Main Power Distribution Panel
1) 6L35, FMCS DATA BASE
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-45-10
ALL ú ú 04 Page 201 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(2) S 032-017Release the fasteners on the front of the ADL.
(3) S 012-018Pull the ADL carefully until you can get acess to the electrical connector.
S 032-011
CAUTION: DO NOT TOUCH THE CONNECTOR PINS OR OTHER CONDUCTORS ON THE ADL.
_______ IF YOU TOUCH THESE CONDUCTORS, ELECTROSTATIC DISCHARGE FROM YOUR BODY CAN CAUSE DAMAGE TO THE ADL.
(4)
Disconect the electrical connector from the rear of the ADL.
S 032-010
(5)
Put a dust cap on the electrical connector.
S 862-004
(6)
Make sure this circuit breaker is closed:
(a) P7 Overhead Circuit Breaker Panel 1) 7F23, LANDING GEAR DSP & CONT ALTN
S 862-006
(7) Prepare the PDL for the software installation:
(a)
Open this circuit breaker and attach DO-NOT-CLOSE tag:
1) P7 Overhead Circuit Breaker Panel a) 7A5, TCAS
(b)
Open access door (117AL) of the electronics compartment to get to the TCAS computer (AMM 06-09-01/201).
S 492-014
CAUTION: MAKE SURE THE POWER ON LIGHT ON THE PDL IS OFF AND POWER IS
_______ REMOVED FROM THE FMCS BEFORE YOU CONNECT THE INTERFACE CABLE. IF YOU DO NOT DO THIS DAMAGE TO THE EQUIPMENT MAY OCCUR.
(8) Connect the PDL interface cable to the PDL.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-45-10
ALL ú ú 04 Page 202 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 492-038
(9)
Connect the other end of the PDL interface cable to the connector on the front of the TCAS computer.
S 862-009
(10)
Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a) P7 Overhead Circuit Breaker Panel
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 导航 NAVIGATION 3(8)