• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-13 08:03来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 34-46-02
 ALL  ú ú 01 Page 301 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
 (3)  S 863-005Remove the DO-NOT-CLOSE tags and close these circuit breakers: (a) P7 Overhead Circuit Breaker Panel 1) 7D9 GND PROX WARN
 (b)  P6 Main Power Distribution Center 1) 6E23 FLT DK LIGHTS PANEL F/O
 (4)  S 863-012Do this task to supply electrical power: (Ref 24-22-00/201). "Manual Control"
 (5)  S 743-008Set the IND LTS switch on the Pilots' Overhead Panel to the TEST position. (a) Make sure the lamps come on.
 (6)  S 863-009If electrical power is not necessary, do this task to remove electrical power: "Manual Control" (AMM 24-22-00/201).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-46-02
 ALL  ú ú 01 Page 302 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 GROUND PROXIMITY WARNING MODULE - REMOVAL/INSTALLATION
______________________________________________________
 1.  General_______
 A.  This subject has two tasks, a removal and an installation of the warning module for the Ground Proximity system.
 B.  The ground proximity warning module (M7990) is on the first officer's instrument panel, P3.
 TASK 34-46-02-004-014
 2.  Ground Proximity Warning Module Removal________________________________________
 A.  Access
 (1)  Location Zone
 222 Control Cabin, RH

 B.  Procedure
 S 864-002
 (1) Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  
P6 Main Power Distribution Panel
 1) 6E23 FLT DK LIGHTS PANEL F/O


 (b)  
P7 Overhead Circuit Breaker Panel
 1) 7D9 GND PROX WARN

 

 S 024-004
 (2)  Remove the warning module:
 (a)  
Loosen the fasteners on the module.

 (b)  
Pull the module from the instrument panel until you can get to the electrical connector.

 (c)  
Disconnect the electrical connector from the module.


 TASK 34-46-02-404-015
 3.  Ground Proximity Warning Module Installation_____________________________________________
 A.  References
 (1)  
24-22-00/201, Manual Control

 (2)  
IPC 34-46-00 Fig. 1


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-46-02
 ALL  ú ú 01 Page 401 ú Jun 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 B. Access
 (1)  Location Zone
 222 Control Cabin, RH

 C. Procedure
 S 864-006
 (1)  Make sure these circuit breakers are open.
 (a)  
P6 Main Power Distribution Panel
 1) 6E23 FLT DK LIGHTS PANEL F/O


 (b)  
P7 Overhead Circuit Breaker Panel
 1) 7D9 GND PROX WARN

 

 S 424-008
 (2)  Install the warning module:
 (a)  
Connect the electrical connector to the module.

 (b)  
Lightly push the module into the instrument panel.

 (c)  
Tighten the fasteners that attach the module to the instrument panel.


 S 864-009
 (3) Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 (a)  
P6 Main Power Distribution Panel
 1) 6E23 FLT DK LIGHTS PANEL F/O


 (b)  
P7 Overhead Circuit Breaker Panel
 1) 7D9 GND PROX WARN

 

 S 864-011
 (4)  Do this task to supply electrical power: "Manual Control"
 (Ref 24-22-00/201).

 (a)  Make sure the module panel lights are on.
 S 864-013
 (5)  If electrical power is not necessary, do this task to remove electical power: "Manual Control" (AMM 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 导航 NAVIGATION 3(33)