S 735-153
(5) Do the center inputs check for label 350:
(a)
Set the captain's ADC source select switch on the P1 captain's main instrument panel to the C position.
(b)
Open these circuit breakers:
1) P7 Overhead Circuit Breaker Panel
a) 7F10 EIU C
b) 7J15 ADC C PWR
(c)
Make sure 1 shows for bit positions 13, 23 and 26.
(d)
Close these circuit breakers:
1) P7 Overhead Circuit Breaker Panel
a) 7F10 EIU C
b) 7J15 ADC C PWR
S 865-154
(6) Prepare the INPUT MONITORING page to monitor E/42/351/00:
NOTE: Label 351 monitors these LRU inputs:
____ -FQPU
-CDU L(R)
-MCP
-IRS L(C,R)
-WBC
-ACARS
-Printer
(a) Push E/42/351/00 on the scratchpad.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-61-00
ALL ú ú 40 Page 519 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
(b) Push the necessary LSK to show E/42/351/00 below the PORT LBL SDI indication. 1) Make sure SAMPLE intermittently shows below E/42/351/00.
S 735-157
(7) Do the inputs check for label 351:
(a) Set the left, center, and right IRS mode select switches to the ALIGN position.
NOTE: The IRS mode select switches are on the P5 pilot's
____
overhead panel.
(b)
Make sure 0 shows for bit positions 11, 12, 13, 14, 15, 16, 17, 18, 20 and 21.
(c)
Set the L-IRS mode select switch to the OFF position.
(d)
Open these circuit breakers:
1) P7 Overhead Circuit Breaker Panel
a) 7C2 FMCS CDU L
b) 7E9 MCP L
c) 7E19 MCP R
d) 7G19 ACARS AC
2) P6 Main Power Distribution Panel
a) 6D5 FUEL QTY 1
b) 6D6 FUEL QTY 2
3) P414 Left Main Power Distribution Panel a) 414K20 WT & BAL b) 414L37 PRINTER AC
(e)
Make sure 1 shows for bit positions 11, 12, 14, 15, 18, 20 and
21.
(f)
Close these circuit breakers:
1) P7 Overhead Circuit Breaker Panel
a) 7C2 FMCS CDU L
b) 7E9 MCP L
c) 7E19 MCP R
d) 7G19 ACARS AC
2) P6 Main Power Distribution Panel
a) 6D5 FUEL QTY 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
34-61-00
ALL ú ú 37 Page 520 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
b) 6D6 FUEL QTY 2
3) P414 Left Main Power Distribution Panel a) 414K20 WT & BAL b) 414L37 PRINTER AC
(g)
Set the R-IRS mode select switch to the OFF position.
(h)
Open this circuit breaker:
1) P7 Overhead Circuit Breaker Panel
a) 7C24 FMCS CDU R
(i)
Make sure 1 shows for bit positions 13, 15, and 16.
(j)
Close this circuit breaker:
1) P7 Overhead Circuit Breaker Panel
a) 7C24 FMCS CDU R
(k)
Set the C-IRS mode select switch to the OFF position.
(l)
Make sure 1 shows for bit position 15, 16, and 17.
S 865-158
(8) Prepare the INPUT MONITORING page to monitor E/42/272/00:
NOTE: Label 272 monitors this input:
____ -Autothrottle ARM switch
(a)
Push E/42/272/00 on the scratchpad for the center CDU.
(b)
Push the necessary LSK to show E/42/272/00 below the PORT LBL SDI indication. 1) Make sure SAMPLE intermittently shows below E/42/272/00.
S 735-159
(9) Do the input check for label 272:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 导航 NAVIGATION 3(176)