 d) 7A14 ADC R PWR
 e) 7A15 ADC R AOA
 f) 7B17 NAV RADIO ILS R
 g) 7B19 NAV RADIO DME R
 h) 7B21 NAV RADIO VOR R

 S 735-153
 (5)  Do the center inputs check for label 350:
 (a)  
Set the captain's ADC source select switch on the P1 captain's main instrument panel to the C position.

 (b)  
Open these circuit breakers:

 1)  P7 Overhead Circuit Breaker Panel
 a) 7F10 EIU C
 b) 7J15 ADC C PWR


 (c)  
Make sure 1 shows for bit positions 13, 23 and 26.

 (d)  
Close these circuit breakers:


 1)  P7 Overhead Circuit Breaker Panel
 a) 7F10 EIU C
 b) 7J15 ADC C PWR

 S 865-154
 (6)  Prepare the INPUT MONITORING page to monitor E/42/351/00:
 NOTE: Label 351 monitors these LRU inputs:
____ -FQPU
 -CDU L(R)
 -MCP
 -IRS L(C,R)
 -WBC
 -ACARS
 -Printer
 (a)  Push E/42/351/00 on the scratchpad.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-61-00
 ALL  ú ú 40 Page 519 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (b)  Push the necessary LSK to show E/42/351/00 below the PORT LBL SDI indication. 1) Make sure SAMPLE intermittently shows below E/42/351/00.
 S 735-157
 (7)  Do the inputs check for label 351:
 (a)  Set the left, center, and right IRS mode select switches to the ALIGN position.
 NOTE: The IRS mode select switches are on the P5 pilot's
____
 overhead panel.

 (b)  
Make sure 0 shows for bit positions 11, 12, 13, 14, 15, 16, 17, 18, 20 and 21.

 (c)  
Set the L-IRS mode select switch to the OFF position.

 (d)  
Open these circuit breakers:


 1)  P7 Overhead Circuit Breaker Panel
 a) 7C2 FMCS CDU L
 b) 7E9 MCP L
 c) 7E19 MCP R
 d) 7G19 ACARS AC

 2)  P6 Main Power Distribution Panel
 a) 6D5 FUEL QTY 1
 b) 6D6 FUEL QTY 2

 3)  P414 Left Main Power Distribution Panel a) 414K20 WT & BAL b) 414L37 PRINTER AC
 (e)
Make sure 1 shows for bit positions 11, 12, 14, 15, 18, 20 and

 21.

 (f)  
Close these circuit breakers:


 1)  P7 Overhead Circuit Breaker Panel
 a) 7C2 FMCS CDU L
 b) 7E9 MCP L
 c) 7E19 MCP R
 d) 7G19 ACARS AC

 2)  P6 Main Power Distribution Panel
 a) 6D5 FUEL QTY 1

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-61-00
 ALL  ú ú 37 Page 520 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 b)  6D6 FUEL QTY 2
 3)  P414 Left Main Power Distribution Panel a) 414K20 WT & BAL b) 414L37 PRINTER AC
 (g)  
Set the R-IRS mode select switch to the OFF position.

 (h)  
Open this circuit breaker:

 1)  P7 Overhead Circuit Breaker Panel
 a) 7C24 FMCS CDU R


 (i)  
Make sure 1 shows for bit positions 13, 15, and 16.

 (j)  
Close this circuit breaker:

 1)  P7 Overhead Circuit Breaker Panel
 a) 7C24 FMCS CDU R


 (k)  
Set the C-IRS mode select switch to the OFF position.

 (l)  
Make sure 1 shows for bit position 15, 16, and 17.


 S 865-158
 (8)  Prepare the INPUT MONITORING page to monitor E/42/272/00:
 NOTE: Label 272 monitors this input:
____ -Autothrottle ARM switch
 (a)  
Push E/42/272/00 on the scratchpad for the center CDU.

 (b)  
Push the necessary LSK to show E/42/272/00 below the PORT LBL SDI indication. 1) Make sure SAMPLE intermittently shows below E/42/272/00.


 S 735-159
 (9)  Do the input check for label 272:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 导航 NAVIGATION 3(176)