REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 52-51-11-400-001 Installation of the Cockpit Door **ON A/C 001-049, 101-105,
R 25-31-41-991-038 **ON A/C 051-099, Fig. 401
R R 25-31-41-991-038-C Fig. 401A **ON A/C 106-149, 201-299,
R 25-31-41-991-038-A **ON A/C 151-199, Fig. 401B
R R 25-31-41-991-038-B Fig. 401C **ON A/C 001-049, 101-105,
R 25-31-41-991-014 **ON A/C 051-099, Fig. 402
R R 25-31-41-991-014-C Fig. 402A **ON A/C 106-149, 201-299,
R 25-31-41-991-014-A **ON A/C 151-199, Fig. 402B
R 25-31-41-991-014-B Fig. 402C
-------------------------------------------------------------------------------
REFERENCE DESIGNATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 101-105,
R 25-31-41-991-018 **ON A/C 051-099, Fig. 403
R R 25-31-41-991-018-C Fig. 403A **ON A/C 106-149, 201-299,
R 25-31-41-991-018-A **ON A/C 151-199, Fig. 403B
R R 25-31-41-991-018-B Fig. 403C **ON A/C 001-049, 101-105,
R 25-31-41-991-019 **ON A/C 051-099, Fig. 404
R R 25-31-41-991-019-C Fig. 404A **ON A/C 106-149, 201-299,
R 25-31-41-991-019-A **ON A/C 151-199, Fig. 404B
R 25-31-41-991-019-B Fig. 404C
CES CES **ON A/C ALL
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R **ON A/C 001-049, 101-105,
25-31-41-991-020 Fig. 405
R **ON A/C 051-099,
R 25-31-41-991-020-B Fig. 405A
R **ON A/C 106-149, 201-299,
R 25-31-41-991-020-A Fig. 405B
R **ON A/C 051-099,
R 25-31-41-991-053 Fig. 406
R **ON A/C 151-199,
R 25-31-41-991-002 Fig. 407
3. Job Set-up
__________ R **ON A/C 001-049, 101-105,
Subtask 25-31-41-860-054
A. Aircraft Maintenance Configuration
(1)
Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
(2)
Make sure that:
(a) On the AIR COND panel 30VU:
-The APU BLEED, the ENG1/2 BLEED and the PACK 1/2 pushbutton switches are in the OFF position.
NOTE : For the APU BLEED the ON legend is off.
____ For the ENG1/2 BLEED the OFF legends are on. For the PACK 1/2 the OFF legends are on.
(b)
The warning notice to tell persons not to operate these pushbutton switches is in position.
(c)
On the HP and LP ground connectors the warning notice is in position to tell persons not to connect the ground air supply.
(3) Make sure that the potable water system is depressurized. WARNING : MAKE SURE THAT THE POTABLE WATER SYSTEM IS DEPRESSURIZED. A
_______ PRESSURIZED SYSTEM CAN CAUSE INJURY TO PERSONS WHEN THEY DO WORK ON IT.