• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:27来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -------------------------------------------------------------------------------2MT STATIC INVERTER 263 831 25-44-41 3MT1 SOCKET-RAZOR LAV A 2036VU 221 831 3MT2 SOCKET-RAZOR LAV D 2036VU 261 831 3MT3 SOCKET-RAZOR LAV F 2036VU 261 831
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,
 (Ref. Fig. 001A) -------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF. -------------------------------------------------------------------------------10MT MINI INVERTER ----200 ----25-44-41
 **ON A/C ALL
 3. System Description
__________________
 **ON A/C 001-049, 051-099, 101-105, 151-152, 201-206,
 (Ref. Fig. 001)
 The razor supply system has:

 -
a circuit breaker,


 -
a static inverter,


 -
a razor socket in each lavatory (US/European type).
 The circuit breaker (1MT) is installed on the panel 2001 VU and protects the
 system.
 The static inverter (2MT) is installed near the panel 2001 VU in the AFT
 cabin overhead-compartment in Zone 263.

 

 EFF : ALL
25-44-00Page 1


R  Razor Supply System - Component Location. Figure 001
 EFF : 001-049, 051-099, 101-105, 151-152, 201-206,  25-44-00 Page 2 Aug 01/05
 CES 

 

 Razor Supply - Component Location Figure 001A 
R  EFF : 106-149, 153-199, 207-299, 301-399, 401-499,  25-44-00 Page 3 Aug 01/05
 CES 

 

 The razor sockets (3MT) are installed in the service cabinets of each lavatory.
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,
 (Ref. Fig. 001A)
 The mini inverter 10MT and a razor power outlet-socket (115V/60HZ) are
 installed in the service cabinet of each lavatory.

 **ON A/C ALL
 4. Power Supply
____________
 **ON A/C 001-049, 051-099, 101-105, 151-152, 201-206,
 (Ref. Fig. 002)
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,
 (Ref. Fig. 002A)
 **ON A/C ALL
 The service bus 212XP supplies 115V AC/400Hz through the circuit breakers (1MT) to a contact in the razor outlet sockets. When a plug is put into a socket, the contact closes and the power is supplied to the static inverter (2MT). The static inverter (2MT) supplies 110V/60Hz to the razor power-outlet socket.
 EFF : ALL
25-44-00Page 4


 Electrical - Schematic Figure 002 
R  EFF : 001-049, 051-099, 101-105, 151-152, 201-206,  25-44-00 Page 5 May 01/05
 CES 

 

 Power Supply - Schematic Figure 002A 
R  EFF : 106-149, 153-199, 207-299, 301-399, 401-499,  25-44-00 Page 6 Aug 01/05
 CES 

 

 RAZOR SUPPLY - ADJUSTMENT/TEST
______________________________
 TASK 25-44-00-710-001
 Operational Test of the Razor Supply System
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
R  No specific circuit breaker(s) safety clip(s) No specific 1 MULTIMETER - STANDARD
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
24-42-00-861-001  Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power
 3. Job Set-up
__________ R **ON A/C 001-049, 051-099, 101-105, 151-152, 201-206,
 Subtask 25-44-00-861-050
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

 EFF : ALL
25-44-00Page 501


 Subtask 25-44-00-865-050
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
2001VU LAV SHAVER SOCKET 1MT 01 E
 OR
 2001VU LAV SHAVER SOCKET 1MT 01 C
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备3(106)