a circuit breaker,
-
a static inverter,
-
a razor socket in each lavatory (US/European type).
The circuit breaker (1MT) is installed on the panel 2001 VU and protects the
system.
The static inverter (2MT) is installed near the panel 2001 VU in the AFT
cabin overhead-compartment in Zone 263.
EFF : ALL
25-44-00Page 1
R Razor Supply System - Component Location. Figure 001
EFF : 001-049, 051-099, 101-105, 151-152, 201-206, 25-44-00 Page 2 Aug 01/05
CES
Razor Supply - Component Location Figure 001A
R EFF : 106-149, 153-199, 207-299, 301-399, 401-499, 25-44-00 Page 3 Aug 01/05
CES
The razor sockets (3MT) are installed in the service cabinets of each lavatory.
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,
(Ref. Fig. 001A)
The mini inverter 10MT and a razor power outlet-socket (115V/60HZ) are
installed in the service cabinet of each lavatory.
**ON A/C ALL
4. Power Supply
____________
**ON A/C 001-049, 051-099, 101-105, 151-152, 201-206,
(Ref. Fig. 002)
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,
(Ref. Fig. 002A)
**ON A/C ALL
The service bus 212XP supplies 115V AC/400Hz through the circuit breakers (1MT) to a contact in the razor outlet sockets. When a plug is put into a socket, the contact closes and the power is supplied to the static inverter (2MT). The static inverter (2MT) supplies 110V/60Hz to the razor power-outlet socket.
EFF : ALL
25-44-00Page 4
Electrical - Schematic Figure 002
R EFF : 001-049, 051-099, 101-105, 151-152, 201-206, 25-44-00 Page 5 May 01/05
CES
Power Supply - Schematic Figure 002A
R EFF : 106-149, 153-199, 207-299, 301-399, 401-499, 25-44-00 Page 6 Aug 01/05
CES
RAZOR SUPPLY - ADJUSTMENT/TEST
______________________________
TASK 25-44-00-710-001
Operational Test of the Razor Supply System
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
R No specific circuit breaker(s) safety clip(s) No specific 1 MULTIMETER - STANDARD
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
__________ R **ON A/C 001-049, 051-099, 101-105, 151-152, 201-206,
Subtask 25-44-00-861-050
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
EFF : ALL
25-44-00Page 501
Subtask 25-44-00-865-050
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU LAV SHAVER SOCKET 1MT 01 E
OR
2001VU LAV SHAVER SOCKET 1MT 01 C
R **ON A/C 106-149, 153-199, 207-299, 301-399, 401-499,