R 4. Procedure_________
R Subtask 25-35-00-710-075
R A. Operational Test of the Refrigerator
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------
R At the refrigerator: R - Push the ON/OFF switch to the ON R position. R R R R R R
R - Set the CHILL/FREEZE switch to the R CHILL position.
R - After a certain time: R R R R
R - Open the door of the refrigeration R compartment.
R - Close the door of the R refrigeration compartment. R R R
R - Set the CHILL/FREEZE switch to the R FREEZE position.
R - After a certain time (approx. 60 R minutes): R R R At the refrigerator:
-
The ON indicator illuminates.
-
The fan and the compressor starts to operate (the noises are heard).
-
The active mode indicator illuminates (CHILL or FREEZE).
-
The FAULT indicator does not come on.
-
The temperature in the refrigeration compartment decreases.
-
The mode indicator CHILL illuminates.
-
The temperature in the refrigeration compartment must be approx. +39 +6 -6 deg.F (+3.88 +3.33 -3.33 deg.C).
-
The compressor is off or will stop operation after a few minutes.
-After a short time, the compressor will start operation.
-
The compressor will stop operation after a few minutes.
-
The temperature in the refrigeration compartment must be approx. +39 +6 -6 deg.F (+3.88 +3.33 -3.33 deg.C).
-
The mode indicator FREEZE illuminates.
-
The temperature in the refrigeration compartment must be approx. +11 +7 -7 deg.F (-11.66 +3.88 -3.88 deg.C).
-
The compressor is off or will stop operation after a few minutes.
EFF : 051-099, 25-35-00Page 536 May 01/05
CES
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - Open the door of the refrigeration R compartment.
R - Close the door of the R refrigeration compartment. R R R
R - Push the ON/OFF switch to the OFF R position.
R 5. Close-up
________
R Subtask 25-35-00-410-062
R A. Close Access
-After a short time, the compressor will start operation.
-
The compressor will stop operation after a few minutes.
-
The temperature in the refrigeration compartment must be approx. +11 +7 -7 deg.F (-11.66 +3.88 -3.88 deg.C).
-All indicators go off.
R (1) Put all CB and switches to the initial configuration.
R (2) Make sure that the refrigerator is in its initial configuration.
R (3) Make sure that the work area is clean and clear of tool(s) and other
R items.
R Subtask 25-35-00-862-073
R B. De-energize the aircraft electrical circuits
R (Ref. TASK 24-41-00-862-002).
EFF : 051-099, 25-35-00Page 537 May 01/05
CES COFFEE MAKER - REMOVAL/INSTALLATION
___________________________________
TASK 25-35-15-000-001
Removal of the Coffee Maker
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information