• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:27来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

24-42-00-861-001 Energize the Ground Service Network from the External Power 38-10-00-614-002 Depressurization of the Potable Water System
R  **ON A/C 151-199, 201-210, 301-399, 401-499,
 25-35-15-991-001 Fig. 401
 **ON A/C 001-049, 101-149, 211-299,
 25-35-15-991-002-A Fig. 402 R **ON A/C 151-199, 201-210, 301-399, 401-499,
 25-35-15-991-002 Fig. 402A
R  EFF : 001-049, 101-149, 151-199, 201-299, 25-35-15Page 401 301-399, 401-499, Aug 01/05
 CES


R  **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 3. Job Set-up
__________
 Subtask 25-35-15-861-052

 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

 Subtask 25-35-15-865-054
 B. At the related galley on the galley control panel
 (1) Open, safety and tag the related circuit breaker(s) of the coffee-maker.
 Subtask 25-35-15-860-050
 C. Aircraft Maintenance Configuration
 (1) De-pressurize the potable water system (Ref. TASK 38-10-00-614-002).
 4. Procedure
_________ R **ON A/C 151-199, 201-210, 301-399, 401-499,
 Subtask 25-35-15-020-050
 A. Removal of the Coffee-Maker (attached with screws)
 (Ref. Fig. 401/TASK 25-35-15-991-001)

 WARNING : DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT
_______
 BURNS WHEN YOU DO THE MAINTENANCE TASK(S).

 (1)
 Remove the screws (1).

 (2)
 Removal of the coffee-maker from the galley WARNING : MAKE SURE THAT THE POTABLE WATER SYSTEM IS DEPRESSURIZED. A


_______ PRESSURIZED SYSTEM CAN CAUSE INJURY TO PERSONS WHEN THEY DO WORK ON IT.
 (a) Carefully pull the coffee-maker (2) to disconnect the electrical connectors and the potable-water supply line.
R  EFF : 001-049, 101-149, 151-199, 201-299, 25-35-15Page 402 301-399, 401-499, Aug 01/05
 CES


 Coffee-Maker attached with screws Figure 401/TASK 25-35-15-991-001 
R  EFF :  151-199, 201-210, 301-399, 401-499,  25-35-15 Page 403 Aug 01/05
 CES 

 

 (b) Remove the coffee maker (2) from the galley.
 (3) Put CAP - BLANKING on the disconnected electrical connectors.
 (4) Put PLUG - BLANKING on the disconnected line ends. R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 25-35-15-020-051
 B. Removal of the Coffee-Maker (attached with a single release pin)
 **ON A/C 001-049, 101-149, 211-299,

 (Ref. Fig. 402/TASK 25-35-15-991-002-A) R **ON A/C 151-199, 201-210, 301-399, 401-499,
 (Ref. Fig. 402A/TASK 25-35-15-991-002) R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 WARNING : DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT
_______
 BURNS WHEN YOU DO THE MAINTENANCE TASK(S).

 (1)
 Pull the lever (1) to the unlocked position.

 (2)
 Removal of the Coffee-Maker from the Galley: WARNING : MAKE SURE THAT THE POTABLE WATER SYSTEM IS DEPRESSURIZED. A


_______ PRESSURIZED SYSTEM CAN CAUSE INJURY TO PERSONS WHEN THEY DO WORK ON IT.
 (a)
 Carefully pull the coffee-maker (2) to disconnect the electrical connector and the potable-water supply line.

 (b)
 Remove the coffee-maker (2) from the galley.


 (3)
 Put CAP - BLANKING on the disconnected electrical connectors.

 (4)
 Put PLUG - BLANKING on the disconnected line ends.


R  EFF : 001-049, 101-149, 151-199, 201-299, 25-35-15Page 404 301-399, 401-499, Aug 01/05
 CES


 Coffee-Maker attached with single release pin Figure 402/TASK 25-35-15-991-002-A 
R  EFF :  001-049, 101-149, 211-299,  25-35-15 Page 405 May 01/05
 CES 

 

 Coffee-Maker attached with single release pin Figure 402A/TASK 25-35-15-991-002 
R  EFF :  151-199, 201-210, 301-399, 401-499,  25-35-15 Page 406 Aug 01/05
 CES 

 

 TASK 25-35-15-400-001
 Installation of the Coffee Maker
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 24-42-00-861-001 Energize the Ground Service Network from the External
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备3(50)