• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:27来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 CES


 (b)
 Slide the Knob (2) to the side until the indicator (4) shows VACANT.

 (c)
 Operate the door latch and pull the lavatory door (3) open.


 (2)
 Bi-folding Doors
 (Ref. Fig. 404/TASK 25-45-19-991-003)


 (3)
 Lift up the spring loaded LAVATORY cover (1).

 (a)
 Slide the knob (2) to the side until the indicator (4) shows VACANT.

 (b)
 Push the lavatory door (3) open and/or release the door latches

 (5) and pull the lavatory door (3) fully open outwards.

 (c)
 Close the lavatory door (3) and lock the door latches (5).

 (d)
 Operate the lavatory door (3) and make sure that the door operation is correct.

 


R **ON A/C 106-149, 218-299, 301-399, 401-499,
 Subtask 25-45-19-710-050-A
 D. Do the Operational Test of the Emergency Opening (from outside of the lavatory) of the Lavatory Doors.
 NOTE : For this test, the lavatory door must be locked from the inside.
____
 (1) Single Bladed Door
 (Ref. Fig. 403A/TASK 25-45-19-991-005-A)

 (a)
 Lift up the spring loaded LAVATORY over (1).

 (b)
 Slide the Knob (2) to the side until the indicator (4) shows VACANT.

 (c)
 Turn the lock pin (5) a quarter turn left or right to release the catch (6).

 (d)
 Pull the lavatory door (3) open.

 (e)
 Push back the catch (6) and turn the lock pin (5) back to the locked position


 EFF : ALL
25-45-19Page 409


 Lavatory Single-Blade Door - Emergency Opening from the Outside Figure 403A/TASK 25-45-19-991-005-A
R EFF : 106-149, 218-299, 301-399, 401-499, 25-45-19Page 410 Aug 01/05
 CES R Lavatory Bi-folding Doors - Emergency Opening from the Outside R Figure 404/TASK 25-45-19-991-003


 EFF : ALL
25-45-19Page 411
Feb 01/04 CES


 (f) Close the door (3).
 (2)
 Bi-folding Doors
 (Ref. Fig. 404/TASK 25-45-19-991-003)


 (3)
 Lift up the spring loaded LAVATORY cover (1).

 (a)
 Slide the knob (2) to the side until the indicator (4) shows VACANT.

 (b)
 Push the lavatory door (3) open and/or release the door latches

 (5) and pull the lavatory door (3) fully open outwards.

 (c)
 Close the lavatory door (3) and lock the door latches (5).

 (d)
 Operate the lavatory door (3) and make sure that the door operation is correct.

 


 **ON A/C ALL
 5. Close-up
________ Subtask 25-45-19-862-050
 A. De-energize the ground service network
 (Ref. TASK 24-42-00-862-001).

 EFF : ALL
25-45-19Page 412
May 01/05
R
 CES


 TASK 25-45-19-960-001
 Replacement of a Lavatory Door Damper

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001  Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power R 25-45-19-991-004 Fig. 405
 3. Job Set-up
__________
 Subtask 25-45-19-861-051

 A. Aircraft Maintenance Configuration
 (1) Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

 4. Procedure
_________
 Subtask 25-45-19-960-050

 A. Replace the Lavatory Door Damper - Sidewall Mounted R (Ref. Fig. 405/TASK 25-45-19-991-004)
 (1) Remove the lavatory door damper (6) as follows:
 (a)
 Open the Lavatory door (1).

 (b)
 Remove the pin (4), the washer (3), the bolt (2) and disconnect the door damper (6) from the door backet (5).

 (c)
 If fitted, remove the pin (7), the washer (8) and the bolt (9).


 EFF : ALL
25-45-19Page 413


R  Lavatory Door Damper - Sidewall Mounted Figure 405/TASK 25-45-19-991-004
 EFF :  ALL  25-45-19 Page 414 Feb 01/04
 CES 

 

 (d) Disconnect the door damper (6) from the sidewall bracket (10) and remove the door damper (6).
 (2) Install the lavatory door damper (6) as follows:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备3(123)