(d)
Make sure that the seal of each decompression panel is in the correct condition.
(e)
Make sure that each decompression panel is in the correct position.
(2)
Lining panels
(a)
Examine each lining panel for cracks and other damage. NOTE : If a lining panel is damaged, do a repair (Ref. TASK 25-
____ 00-00-200-001) or replace the panel.
(b)
Make sure that the lining panels are correctly attached.
(3)
Floor panels
(a) Examine each floor panel for:
-impact damage
-deep scratches
-cracks
-deformation
-delamination.
EFF : ALL
25-50-00Page 607
May 01/05
R
CES
Decompression Panel Figure 601/TASK 25-50-00-991-006
R EFF : CES ALL 25-50-00 Page 608 Nov 01/04
(b)
If a floor panel is damaged, do a repair (Ref. ASRM 530200100) (Ref. ASRM 530200100) or replace the panel (Ref. TASK 53-22-14-000-001) (Ref. TASK 53-42-14-000-001) or (Ref. TASK 53-22-14-400-001) (Ref. TASK 53-42-14-400-001).
(c)
Make sure that the floor panels are correctly attached.
(d)
Make sure the sealant at the floor panel joints is in the correct condition.
(e)
If the sealant is damaged, repair it (Ref. TASK 51-76-11-300-001).
5. Close-up
________
Subtask 25-50-00-860-051
A. Make sure that the work area is clean and clear of tool(s) and other items.
R **ON A/C 001-049, 101-105,
Subtask 25-50-00-865-058
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
For the FWD cargo compartment
2MY and 3MY
For the AFT cargo compartment
102MY and 103MY
**ON A/C ALL
Subtask 25-50-00-410-060-A
C. Close Access
(1)
Remove the access platform(s).
(2)
Remove the actuator safety locks and close the FWD and/or AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
EFF : ALL
25-50-00Page 609
**ON A/C 301-399,
TASK 25-50-00-210-002
1. Reason for the Job
Operational Test and Detailed Visual Inspection of YZ-Door Sill Latches. __________________ Refer to the MPD TASK: 255000-03
2. Job Set-up Information______________________ Not Applicable
3. Job Set-up__________
4. Procedure_________ ________
5. Close-up
Subtask 25-50-00-865-077-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
For the FWD cargo compartment
2MY and 3MY
CARGO COMPARTMENTS - REPAIRS
____________________________
TASK 25-50-00-300-001
Repair of the Door Nets and the Divider Nets
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific fabric, part number TF60-0524122 No specific permanent marker pen No specific sewing thread, part number ST10-0800402 or
ST20-0801201 No specific webbing, part number TW20-0512701 No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE No specific 1 WARNING NOTICE
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump CMM 25-52-28 CMM 255228 (for corrective action) 25-50-00-991-015 Fig. 801 25-50-00-991-016 Fig. 802 25-50-00-991-017 Fig. 803 25-50-00-991-018 Fig. 804
EFF : ALL
25-50-00Page 801
3. Job Set-up
__________ Subtask 25-50-00-861-051
A. Energize the Ground Service Network (Ref. TASK 24-42-00-861-001). Subtask 25-50-00-010-092
B. Get Access
(1)
Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the opening of the FWD and/or AFT cargo-compartment door(s).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备3(143)