CES
Fill Soap Dispenser
Figure 402/TASK 25-45-14-991-002
CES
Fill Soap Dispenser Figure 402A/TASK 25-45-14-991-002-A
EFF : 004-049, 053-099, 101-105, 151-199, 201-228, 301-302, 25-45-14 Page 412 May 01/05
CES
R **ON A/C 106-149, 229-299, 303-399, 401-499,
Subtask 25-45-14-420-050-A
B. Installation of the Soap Dispenser (Ref. Fig. 401B/TASK 25-45-14-991-001-B)
R R (1) Put the soap outlet (2) and the seal (3) in position on the wash basin assembly and install and tighten the nut (4).
(2) Install the knurled nut (5) and the soap bottle (6).
R R R (3) Install the pump assembly (1) in the soap outlet (2) and tighten it clockwise with your hand.
(4) Make sure that the work area is clean and clear of tool(s) and other items.
(5) Close the access door.
Subtask 25-45-14-613-050-A
C. Servicing of the Soap Dispenser
CAUTION : DO NOT USE INDUSTRIAL HAND CLEANERS, NATURAL SOAPS AND CLEANING_______ AGENTS THAT CONTAIN ABRASIVES, SOLVENTS OR A LARGE PROPORTION OF DISINFECTANT. THESE MATERIALS CAN CAUSE THE PUMP MECHANISM TO WEAR MORE QUICKLY.
R
NOTE : The dispenser is applicable for normal liquid hand-cleaning____ agents, soap creams and dish-washing agents for household use. We recommend that you use mild, biodegradable, fully synthetic agents.
R (1) Fill the bottle (6) of the soap dispenser. (Ref. Fig. 402B/TASK 25-45-14-991-002-B)
R R (a) Turn the pump-assembly (1) counter-clockwise with your hand and remove it from from the soap outlet (2).
(b) Use a FUNNEL and fill the bottle with weak liquid soap.
CES
R R Soap Dispenser Figure 402B/TASK 25-45-14-991-002-B
R EFF : 106-149, 229-299, 303-399, 401-499, 25-45-14 Page 414 Aug 01/05
CES
R R (c) Install the pump assembly (1) in the soap outlet (2) and tighten it clockwise with your hand.
R R (d) Operate the pump assembly (1) several times until soap comes out of the soap outlet (2).
(e) Remove the unwanted soap with a lint-free cotton cloth MISCELLANEOUS (Material No. 19-003).
(f) Make sure that the work area is clean and clear of tool(s) and other items.
**ON A/C ALL
Subtask 25-45-14-710-050
D. Do an Operational Test of the Soap Dispenser
(1) Press the spout on the soap dispenser and make sure that the dispenser operates correctly.
5. Close-up________
Subtask 25-45-14-862-050
A. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
EFF : ALL
25-45-14Page 415
FLAP - WASTE CHUTE - REMOVAL/INSTALLATION
_________________________________________
TASK 25-45-15-000-001
Removal of the Waste Chute Flap
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power
**ON A/C 001-049, 051-058, 101-101,
25-45-15-991-001 Fig. 401
R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499, Post SB 25-1226 For A/C 004-049,053-058,101-101, 25-45-15-991-001-A Fig. 401A **ON A/C ALL
3. Job Set-up
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备3(116)