R  - Let the unit operate for 
R  approx. 10 min. 
R  - Open the hot water faucet to 
R  empty the water-heater tank. 
R  - Close the hot water faucet. 


R  - Switch the ON/OFF switch to the 
R  off position. 
R  **ON A/C 106-149, 151-199, 201-299,
 Subtask 25-35-00-710-074-B

On the water-heater:
-
The unit fills with water.

-
The NO WATER indicator goes off until the tank is full.

-
The READY indicator comes on.

-
The READY indicator goes off.

-
The unit fills with water.


-After a short time, the READY indicator comes on.
-All indicators go off.
 A. Do the Operational Test of the Water-Heater
 (1) Use a CONTAINER 5 L(1 1/2 USGAL) to collect the water from the water faucet during this test.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the galley:
 -Close the potable water shut
 off valve.

 2. On the water-heater:
 -Open the hot water faucet until
 waterflow stops.

 -Close the hot water faucet.
 3. On the water-heater: On the water-heater:
 EFF : 051-099, 106-149, 151-199, 201-299, 25-35-00Page 531 May 01/05
 CES


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
-Push the ON/OFF pushbutton to the on position.
4. At the galley:
 -Open the potable water shut off valve.
 5. On the water-heater:
-Open the hot water faucet to bleed air from the tank until water comes from the faucet.
-Close the hot water faucet.
 -Let the unit operate for
approx. 10 min.

 -Open the hot water faucet to empty the water-heater tank.
 -Close the hot water faucet.
-Push the ON/OFF pushbutton to the off position.
-
The ON/OFF indicator comes on.

-
The NO WATER indicator comes on.


On the water-heater:
-
The unit fills with water.

-
The NO WATER indicator goes off untilthe tank is full.

-
The READY indicator comes on.

-
The READY indicator goes off.

-
The unit fills with water.


 -After a short time, the READY indicator comes on.
-All indicators go off.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
 5. Close-up
________
 Subtask 25-35-00-410-061

 A. Close Access
 (1)
 Put all related C/B and switches to their initial configuration.

 (2)
 Make sure that the water-heater is in its initial configuration.

 (3)
 Depressurize the potable water system (Ref. TASK 38-10-00-614-002).

 (4)
 Make sure that the work area is clean and clear of tool(s) and other items.

 


 Subtask 25-35-00-862-072
 B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).


R  **ON A/C 051-099, 
R  TASK 25-35-00-710-024 
R  Operational Test of the Refrigerator 
R  1. Reason for the Job__________________ 
R  Self Explanatory 
R  2. Job Set-up Information______________________ 
R  A. Referenced Information 
R  -------------------------------------------------------------------------------
R  REFERENCE  DESIGNATION 
R  -------------------------------------------------------------------------------
R  24-41-00-861-002  Energize the Aircraft Electrical Circuits from the 
R  External Power 
R  24-41-00-862-002  De-energize the Aircraft Electrical Circuits Supplied 
R  from the External Power 
R  3. Job Set-up__________ 
R  Subtask 25-35-00-861-073 
R  A. Energize the aircraft electrical circuits 
R  (Ref. TASK 24-41-00-861-002).

 CES  CES


R  Subtask 25-35-00-865-078 
R  B. Make sure that this(these) circuit breaker(s) is(are) closed: 
R  -------------------------------------------------------------------------------
R  PANEL  DESIGNATION  IDENT. LOCATION 
R  -------------------------------------------------------------------------------
R  **ON A/C 051-060, 
 